Appendix B: HP SNMP events 34
Trap types Rules file Description
Netcool
severity
cpqSasLogDrvStatusChange
(5023)
This event occurs when the status
of a SAS or SATA logical drive
changes.
CpqSasLogDrvStatus:ok
CpqSasLogDrvStatus.
2
Clear (0)
CpqSasLogDrvStatus:degraded
CpqSasLogDrvStatus.
3
Minor (3)
CpqSasLogDrvStatus:rebuilding
CpqSasLogDrvStatus.
4
Minor (3)
CpqSasLogDrvStatus:failed
CpqSasLogDrvStatus.
5
Critical (5)
CpqSasLogDrvStatus:offline
CpqSasLogDrvStatus.
6
Critical (5)
CpqSas2TapeDrvStatusChange
(5025)
This event occurs when the status
of a SAS tape drive changes.
cpqSasTapeDrvStatus: ok
cpqSasTapeDrvStatus
.2
Clear (0)
cpqSasTapeDrvStatus: offline
cpqSasTapeDrvStatus
.3
Critical (5)
Server health features (CPQHLTH.MIB)
Trap types Rules file Description
Netcool
severity
cpqHe3CorrectableMemoryLogD
isabled (6016)
This event occurs when the
frequency of correctable memory
errors is so high that the error
tracking logic has been
temporarily disabled.
cpqHeCorrMemLogStatus:notSup
ported
cpqHeCorrMemLogSt
atus.2
Minor (3)
cpqHeCorrMemLogStatus:disabl
ed
cpqHeCorrMemLogSt
atus.3
Major (4)
cpqHeCorrMemLogStatus:enable
d
cpqHeCorrMemLogSt
atus.4
Clear (0)
cpqHe3ThermalTempFailed
(6017)
6017
This event occurs when the
temperature status has been set to
fail.
Critical (5)
cpqHe3ThermalTempDegraded
(6018)
This event occurs when the server's
temperature is outside of the
normal operating range.
cpqHeThermalDegradedAction:c
ontinue
cpqHeThermalDegra
dedAction.2
Major (4)
cpqHeThermalDegradedAction:s
hutdown
cpqHeThermalDegra
dedAction.3
Major (4)