Hp Insight Management for Tivoli Manual de usuario Pagina 70

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 270
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 69
Appendix B: HP SNMP events 70
Trap types Rules file Description
Netcool
severity
CpqCmcStatusAux2:noSensor
CpqCmcStatusAux2.
4
Minor (3)
cpqCmcalarm1 (153017)
This event occurs when Alarm 1
is set from Network
management.
CpqCmcStatusAlarm1:ok
CpqCmcStatusAlarm
1.2
Clear (0)
CpqCmcStatusAlarm1:alarm
CpqCmcStatusAlarm
1.3
Major (4)
cpqCmcalarm2 (153018)
This event occurs when Alarm 2
is set from Network
management.
CpqCmcStatusAlarm2:ok
CpqCmcStatusAlarm
2.2
Clear (0)
CpqCmcStatusAlarm2:alarm
CpqCmcStatusAlarm
2.3
Major (4)
cpqCmcalarmLock1Dev (153019)
This event occurs when the rack
door locking device #1 fails.
CpqCmcStatusLock1Dev:ok
CpqCmcStatusLock1
Dev.2
Clear (0)
CpqCmcStatusLock1Dev:powerFa
il
CpqCmcStatusLock1
Dev.3
Major (4)
CpqCmcStatusLock1Dev:lowBatte
ry
CpqCmcStatusLock1
Dev.4
Minor (3)
CpqCmcStatusLock1Dev:replaceB
att
CpqCmcStatusLock1
Dev.5
Major (4)
CpqCmcStatusLock1Dev:missingB
att
CpqCmcStatusLock1
Dev.6
Minor (3)
CpqCmcStatusLock1Dev:noConne
ct
CpqCmcStatusLock1
Dev.7
Minor (3)
CpqCmcStatusLock1Dev:notAvail
CpqCmcStatusLock1
Dev.8
Minor (3)
cpqCmcalarmLock2Dev (153020)
This event occurs when the rack
door locking device #2 fails.
CpqCmcStatusLock2Dev:ok
CpqCmcStatusLock2
Dev.2
Clear (0)
CpqCmcStatusLock2Dev:powerFa
il
CpqCmcStatusLock2
Dev.3
Major (4)
CpqCmcStatusLock2Dev:lowBatte
ry
CpqCmcStatusLock2
Dev.4
Minor (3)
CpqCmcStatusLock2Dev:replaceB
att
CpqCmcStatusLock2
Dev.5
Major (4)
CpqCmcStatusLock2Dev:missingB
att
CpqCmcStatusLock2
Dev.6
Minor (3)