HP Smart Update Manager User Guide
Version 6.0.0
Abstract
This document describes how to use HP SUM to apply firmware updates to HP ProLiant and HP Integrity servers, and apply
software updates to HP ProLiant servers. This document is intended for individuals who understand the configuration and
operations of Microsoft Windows, Windows Server, Linux, smart components, HP-UX, VMware, and the risk of data loss from
performing updates.
HP Part Number: 613175-401a
Published: November 2013
Edition: 2
Vista de pagina 0
1 2 3 4 5 6 ... 76 77

Indice de contenidos

Pagina 1 - Version 6.0.0

HP Smart Update Manager User GuideVersion 6.0.0AbstractThis document describes how to use HP SUM to apply firmware updates to HP ProLiant and HP Integ

Pagina 2

2 Downloading, installing, and launching HP SUMDownloading HP SUMDownloading HP SUM from the HP SUM websiteYou can download the latest version of HP S

Pagina 3 - Contents

The script supports the following options:DefinitionOptionContinue the migration without using prompts./yPrint the script help./hThis option creates a

Pagina 4 - 4 Contents

For a complete list of HP ProLiant systems and software supported by SPP, and updates availablein an SPP release, see the HP Service Pack for ProLiant

Pagina 5 - Contents 5

The following table describes when typical HP SUM deployment scenarios are used.Used whenScenarioGraphical deployment on a local host• You are not fam

Pagina 6 - 6 Contents

the BitLocker Drive Encryption can be re-enabled. Once the BitLocker Drive Encryption has beenre-enabled, the plain text key is removed and BitLocker

Pagina 7 - 1 Introduction

SUM using the sudo command. If you are using Windows Server 2012, you must log in with theAdministrator account, or select Run as Administrator.NOTE:

Pagina 8

3 Using the HP SUM GUIUsing the Home screenWhen you launch HP SUM, HP SUM displays the Home screen. From this screen, you can clickGuided Update, Base

Pagina 9 - HP SUM new terms

Using Guided Update in Interactive mode1. In the navigation menu, click Guided Update.2. Click Interactive.3. Click OK.4. HP SUM displays the baseline

Pagina 10 - Downloading HP SUM

Using the Baseline Library screenThe Baseline Library screen displays the baselines and additional packages you will use to updateyour nodes. Baseline

Pagina 11 - Deploying HP SUM

Follow these steps:To add this baseline:c. Enter the username, required.d. Enter the password, requiredNOTE: HP SUM does not support mapped UNCdrives.

Pagina 12 - Deployment scenarios

© Copyright 2009, 2013 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or

Pagina 13

5. Select Make Bootable ISO file if you want to create a bootable ISO with your baseline.If you choose to make a bootable ISO, click Browse and choose

Pagina 14 - Launching HP SUM

Deleting a baselineHP SUM does not support deleting a baseline if it is associated with a node.To delete a baseline:1. On the Baseline Library screen,

Pagina 15 - Logging out of the HP SUM GUI

NOTE: The details that HP SUM displays vary based on the node type.NOTE: If this is the first time you are running HP SUM 6, and have set up targets i

Pagina 16 - 3 Using the HP SUM GUI

3. Enter a description for the node.4. In the Type field, select the node type. If you do not know the node type, select Unknown.During the inventory

Pagina 17 - Using Guided Update 17

Adding a node by searching a range of IP addresses1. From the Nodes screen, click Add Node.2. Click Find Nodes.3. Enter a range of IP addresses for HP

Pagina 18 - Adding a baseline

Editing a node1. From the Nodes screen, highlight the node and then click Actions→Edit.2. Change the items you want to edit:• Description• TypeNOTE: S

Pagina 19 - Creating a custom baseline

NOTE: If you perform inventory on an OA node, HP SUM automatically adds and inventoriesthe associated nodes if you select the check box on the Add Nod

Pagina 20 - 20 Using the HP SUM GUI

the version number. If you are deploying a Linux node, HP SUM displays only RPM updatesthat are valid for your node.NOTE: You can click Force to downg

Pagina 21 - Using the Nodes screen

Node reportsYou can generate reports that give details about the node firmware, software, and driver details,components you can install, failed depend

Pagina 22 - Adding a node

Server overviewWhen you select a node, the Server Overview screen displays a progress bar for inventory anddeployment of the node, and information abo

Pagina 23 - Using the Nodes screen 23

Contents1 Introduction...7HP SUM overview...

Pagina 24 - 24 Using the HP SUM GUI

Enclosure inventory1. From the Enclosures screen, highlight the enclosure on which you want to take inventory.2. Click Actions→Inventory.3. The Enclos

Pagina 25 - Node inventory

Deploying a server1. From the Servers screen, highlight the server you want to deploy.2. Click Actions→Deploy.3. The Server Deploy procedure is the sa

Pagina 26 - Deploying a node

Switch reports1. From the Switches screen, highlight the switch for which you want to generate reports.2. Click Actions→Reports.3. The Switch Reports

Pagina 27 - Using the Nodes screen 27

Deleting a VM host1. From the VM hosts screen, highlight the VM host.2. Click Actions→Delete.3. Click, Yes, delete.Using the iLO screenThe iLO screen

Pagina 28 - Deleting a node

Adding an iPDU1. From the iPDU screen, click Actions→Add.2. The Add iPDU procedure is the same as the Add Node procedure. For more information, see“Ad

Pagina 29 - Using the Enclosures screen

Editing a Virtual Connect1. From the Virtual Connects screen, highlight the Virtual Connect you want to edit.2. Click Actions→Edit.3. The Edit Virtual

Pagina 30 - Using the Servers screen

4 Using legacy scripts to deploy updatesCommand-line interfaceYou can use the HP SUM command-line interface to script custom installations.Command-lin

Pagina 31 - Using the Switches screen

Switch update commandsG7 and earlier servers do not support AMS agents. The following tables show what updates occurwhen you use the switch agent comm

Pagina 32 - Using the VM Hosts screen

DescriptionInstallation optionsRewrites the current version of firmware for multi-nodedevices such as hard drives and array controllers (appliesto fir

Pagina 33 - Using the iLO screen

DescriptionInstallation optionsThis argument is a filter switch. It enables you to installnewer versions of components defined in a PSP, ISP, orfirmwa

Pagina 34 - 34 Using the HP SUM GUI

Using the Servers screen...30Adding a server...

Pagina 35

DescriptionInstallation optionsand are not installed unless this argument is used. Whenthe /use_wmi argument is used, and the /use_snmp &/use_ams

Pagina 36 - Command-line interface

DescriptionOverriding errorsdo not have dependency failures. Force attempts allupdates, even if they have dependency failures.DescriptionReboot option

Pagina 37 - Command-line arguments

DescriptionNodes/su_username cannot be used with /use_sudo accesslevel.NOTE: Specifying /targettype linux reducesinventory time for deployments. This

Pagina 38

DescriptionNodesIf the node name includes spaces, make sure you enclosethe name in quotation marks, “ “.NOTE: /targettype is an optional command linea

Pagina 39

DescriptionGenerating reportsfile name formats ofHPSUM_Report_<date>_<time>.html andHPSUM_Report_<date>_<time>.xml.By default,

Pagina 40

DescriptionSuperdome 2 server commandsExample: /device_listnpar1,npar2,blade1/1,blade1/2Use this argument when the /update_type is ALL orPARTITIONS. T

Pagina 41

Either of the following command-line inputs can deploy two software components:• hpsum /f:software cp008097.exe cp008257.exe• hpsum /c cp008097.exe /c

Pagina 42

Windows smart-component return codesMeaningReturn codeThe smart component was not installed. For moreinformation, see the log file.0The smart componen

Pagina 43

MeaningReturn codeThe installer cannot run because of an un-met dependencyor installation tool failure.6The actual installation operation (not the ins

Pagina 44

For parameters that can take list values, list separators can be commas, semicolons, or spaces.NOTE: The credentials can be omitted from the file for

Pagina 45

Command-line arguments...37Command-line examples...

Pagina 46 - Return codes

Error reportingIf errors occur in the input file, HP SUM exits with a return value of –2 (bad parameter). The detailsof the location and nature of the

Pagina 47 - Multi-node servers:

Possible valuesDescriptionParameterYES, NOForces updates to softwarecomponents.FORCESOFTWAREYES, NOEnables you to override or downgradean existing ins

Pagina 48 - Input files

Possible valuesDescriptionParameterDirectory pathProvide a single local baseline path.This action creates an inventory fromSOURCEPATHthe given path in

Pagina 49 - File encoding

Possible valuesDescriptionParameterYES, NOThis is a filter switch that allows youto view only the firmware componentsrequired for installation.ROMONLY

Pagina 50 - Input file parameters

Possible valuesDescriptionParameterIP address, DNS nameThis parameter is the IP address or theDNS name of a remote server, remoteNODEiLO NIC port, Vir

Pagina 51

Possible valuesDescriptionParameterstarted when the health applicationloads. (Applies to Linux SPP only.)Determines whether the HP SystemsInsight Mana

Pagina 52

Possible valuesDescriptionParameterList of IP address ranges separatedby semicolons (for example,10.1.1.1-10.1.1.10;HP Systems Management Homepageuses

Pagina 53

Possible valuesDescriptionParameterServer DNS nameEnables you to provide a list ofservers, separated by semicolons, forXENAMELISTtrust relationships f

Pagina 54

Possible valuesDescriptionParameter<superusername>Use this argument to provide asuperuser username.SUUSERNAMESUUSERNAME cannot be used withUSESU

Pagina 55

PWD = root123HOST = 234.567.765.432[END]USAGE: hpsum /inputfile <path:\inputfile.txt>Examples of inputfile.txt file:Example: The two nodes are p

Pagina 56

HP SUM does not generate reports for nodes that are offline...68HP SUM displays only requested reports

Pagina 57

HOST=16.83.62.141UID=UseridPWD=password[END][TARGETS]HOST=16.83.61.48UID=UseridPWD=password[END][TARGETS]HOST=16.83.62.196UID=UseridPWD=password[END][

Pagina 58

HOST = 10.0.1.7UID = UseridPWD = password[END][TARGETS]HOST = 10.0.1.73UID = UseridPWD = password[END]Example: Using super user to update Linux compon

Pagina 59 - Input files 59

can specific a repository by using other command-line parameters to generate reports. For specificcommands, see “Command-line interface” (page 36).Rep

Pagina 60

5 Advanced topicsConfiguring IPv6 networksYou can deploy to remote nodes in IPv6-based networks for Windows and Linux node servers.Using HP SUM with I

Pagina 61 - Reports 61

Table 2 HP SUM Windows network ports (continued)DescriptionPortsDefault for some internal communications. This port listens on the remote sideif there

Pagina 62

6 TroubleshootingCollecting trace directoriesHP SUM generates a set of debug trace logs located in the %TEMP%\HPSUM directory on Windowssystems. These

Pagina 63 - 5 Advanced topics

FunctionLog FilesContains information of HP SUM discovery, installationstatus and errors if any.<target>\hpsum_log.txt<target> is the name

Pagina 64 - GatherLogs

HP SUM does not display the Deploy button on the Deploy Nodes screenSolution: Make sure that HP SUM has resolved all dependencies before attempting to

Pagina 65 - 6 Troubleshooting

HP SUM displays the message Ready for deployment while HP SUM isperforming inventory on a nodeSolution: Make sure that HP SUM completes an inventory b

Pagina 66 - Node troubleshooting

HP SUM service troubleshootingHP SUM service stops running when HP SUM is mounted from a virtual media sourceSolution: Do not mount a virtual media so

Pagina 67 - Node troubleshooting 67

1 IntroductionHP SUM overviewHP SUM is a technology included in many HP products for installing and updating firmware andsoftware on HP ProLiant serve

Pagina 68 - Reports troubleshooting

7 Support and other resourcesContacting HPFor worldwide technical support information, see the HP support website:http://www.hp.com/supportBefore cont

Pagina 69

To download the latest SPP and available hot fixes, see the SPP download page:http://www.hp.com/go/spp/downloadFor information about HP Subscriber&apo

Pagina 70 - 7 Support and other resources

IMPORTANT: Provides clarifying information or specific instructions.NOTE: Provides additional information.TIP: Provides helpful hints and shortcuts.HP

Pagina 71 - Typographic conventions

8 Documentation feedbackHP is committed to providing documentation that meets your needs. To help us improve thedocumentation, send any errors, sugges

Pagina 72 - HP Insight Online

GlossaryAMS Agentless Management ServiceAnalyze The process where HP SUM verifies all dependencies before deploying updatesBaseline A set of updates f

Pagina 73 - 8 Documentation feedback

IndexAabort updateenclosure, 29iLO, 33iPDU, 34servers, 30switch, 31Virtual Connects, 35VM host, 32activity, 16addbaseline, 18addingenclosures, 29iLO,

Pagina 74 - Glossary

Input file format and rules, 49Input files, 48GGUIusing, 16Guided Update, 16Hhealth icon, 9helpobtaining, 70HPtechnical support, 70HP Insight Online,

Pagina 75

runningHP SUM, 11Sscreen components, 8scripted deployment, 36servers, 30abort update, 30adding, 30delete, 31deploy, 31edit, 30inventory, 30report, 31,

Pagina 76 - 76 Index

NOTE: HP SUM does not support third-party controllers. This includes flashing hard drivesbehind these controllers.• Remote online deployment of I/O Ca

Pagina 77