StatusDescriptionItem
Green = The data transfer rate is 4 Gbps.FC link speed (S) LED5
Off = The data transfer rate is 2 Gbps.
Blinking white = RAID controller is selected (for identification purposes only).Unit locator LED6
Off = Not active.
Blue = The RAID controller can be removed.OK to remove LED7
Off = The RAID controller is not prepared for removal.
Yellow = A fault has been detected or a service action is required.Fault/Service required
LED
8
Blinking yellow = A hardware-controlled power on or a cache flush or restore error
occurred.
Green = RAID controller is operating normally.Power On/OK LED9
Off = RAID controller is not OK.
Green = Cache is dirty (contains unwritten data) and operation is normal.Cache status LED10
Blinking green (1 Hz) = A Compact Flash flush is in progress.
Blinking green (10 Hz) = A cache self-refresh is in progress. Valid data will remain
until supercaps have drained, approximately 15 minutes.
Off = Cache is clean (contains no unwritten data).
Blinking green = At least one FC port has I/O activity.Fibre Channel port
activity LED
11
Off = The FC ports have no I/O activity.
Green = The Ethernet link is up.Ethernet link status LED12
Off = The Ethernet port is not connected or the link is down.
Blinking green = The Ethernet link has I/O activity.Ethernet activity LED13
Off = The Ethernet link has no I/O activity.
Green = The port link is connected.SAS port status LED14
Off = The port is empty or the link is down.
1
Some power supply models do not have a power switch. In this case, power down the enclosure by unplugging the
power cords from the enclosure.
Capacity Enclosure
StatusDescriptionItem
Toggle, where O is Off.Power switch
1
1
Green = AC power is on and input voltage is normal.AC Power Good LED2
Off = AC power is off or input voltage is below the minimum threshold.