B.72
statport
Remote Copy User’s Guide InForm OS Version 2.3.1
Specifies the minimum threshold using any integer. The integer can be optionally
followed with
k or K to indicate a multiple of 1000, m or M to indicate a multiple of
1000000, or g or G to indicate a multiple of 1000000000.
An example of this option in use is
–filt curs,r,iops,10k that indicates that statistics
for a device that has more than 10,000 current read-only I/O operations are displayed.
–ni
Shows only nonidle devices. This option is shorthand for the option –filt
curs,t,iops,0
.
SPECIFIERS
None.
RESTRICTIONS
The –filt option applies to data transfers only.
EXAMPLE
The following example displays one iteration of I/O statistics for all ports:
The columns in the example above are identified as follows:
Port. The port ID.
D/C. The Data or Control transfers.
r/w. The I/O type. Values can be read (r), write (w), or read and write (t).
cli% statport -iter 1
11:32:25 06/01/07 r/w I/O per second KBytes per sec Svt ms IOSz KB
Port D/C Cur Avg Max Cur Avg Max Cur Avg Cur Avg Qlen
0:0:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
0:0:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
0:2:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
0:2:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
0:3:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
0:3:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
1:0:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
1:0:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
1:3:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
1:3:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
------------------------------------------------------------------------
total Data t 0 0 0 0 0.0 0.0 0.0 0.0 0