7. Utility Reference
343
Legend:
path_health_check Specify one of the following values to
indicate whether to enable or disable the
path health check function:
on: Enabled (default)
off: Disabled
Optional Optional 3
path_health_check_in
terval
Specify the interval in minutes at which the
path health check is performed.
You can specify a check interval from
1 to
1440. The default is 30.
Optional Optional 4
auto_failback Specify one of the following values to
indicate whether to enable or disable the
automatic failback function for failed paths:
on: Enabled (default)
off: Disabled
Optional Optional 3
auto_failback_interv
al
Specify the interval in minutes from the time
the previous path status check finished until
the time the next path status check started.
You can specify a check interval from 1 to
1440. The default is 60.
Optional Optional 4
intermittent_error_m
onitor
#3, #4
Specify one of the following values to
indicate whether to enable or disable
intermittent error monitoring:
on: Enabled
off: Disabled (default)
Optional Optional 3
intermittent_error_m
onitor_interval
#4
Specify the interval in minutes that
monitoring for intermittent errors is
performed.
You can specify a check interval from
1 to
1440. The default is 210.
Optional Optional 4
intermittent_error_m
onitor_number
#4
Specify the number of times an error (that is
assumed to be an intermittent error) occurs.
You can specify a value from
1 to 99. The
default is
3.
Optional Optional 2
Key name
#1
Description
#2
Necessity of
definition
Maxim
um
numbe
r of
charac
ters
New
installat
ion
Upgrad
e
installat
ion or
re-insta
llation
Vista de pagina 364