Hp StorageWorks 500 Modular Smart Array Manual de usuario Pagina 108

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 157
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 107
Display Messages
C-16 HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages continued
Message Type Description Action
66 CACHE
HARDWARE FAILED
AND DISABLED
Error The cache memory has
experienced a hardware
failure.
If the MSA500 system is
currently involved in host
I/O:
1. Remove the standby
array controller.
2. Wait 10 seconds.
3. Reinstall the controller,
and be sure that it
seats fully in the
chassis.
If this action does not solve
the problem, wait until
downtime is available and
do the following:
1. Power down the
MSA500 system.
2. Remove both array
controllers.
3. Reinstall both array
controllers, and be sure
that they seat fully in
the chassis.
If this action does not solve
the problem, contact HP
support.
continued
Vista de pagina 107
1 2 ... 103 104 105 106 107 108 109 110 111 112 113 ... 156 157

Comentarios a estos manuales

Sin comentarios