Display Messages
C-20 HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages continued
Message Type Description Action
73 CACHE
HARDWARE
BATTERIES
MISSING
Error The cache memory
batteries are missing.
If the MSA500 system is
currently involved in host
I/O:
1. Remove the standby
array controller.
2. Wait 10 seconds.
3. Reinstall the controller,
and be sure that it
seats fully in the
chassis.
If this action does not solve
the problem, wait until
downtime is available and
do the following:
1. Power down the
MSA500 system.
2. Remove both array
controllers.
3. Reinstall both array
controllers, and be sure
that they seat fully in
the chassis.
If this action does not solve
the problem, contact HP
support.
80 REPLACEMENT
DRIVE FOUND BOX
#<n> BAY <n>
Informational A SCSI drive that was
previously missing or
failed has been replaced
with a working SCSI
drive.