Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide C-25
Table C-1: Display Messages continued
Message Type Description Action
106 VOLUME #<n>
STATE WAITING TO
REBUILD
Informational The configured volume is
waiting before rebuilding
data on a physical drive
that replaces a
previously failed drive.
The rebuild may not
have started yet because
the array controller is
already performing a
rebuild on another
configured volume.
107 VOLUME #<n>
STATE WAITING TO
EXPAND
Informational The configured volume is
waiting to start a volume
expansion operation.
The expansion may have
not started yet because
another configured
volume is undergoing
expansion or a rebuild is
occurring on the
configured volume.