Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide C-7
Table C-1: Display Messages continued
Message Type Description Action
45 REDUNDANCY
FAILED MISMATCH
FIRMWARE
Error Controller Firmware Auto
Cloning has failed.
Both array controllers
must be running the
same version of firmware
for redundant mode.
Manually update the
firmware on the older array
controller.
46 REDUNDANCY
HALTED EXPAND
ACTIVE
Informational If volume expansion is in
progress, redundancy is
not supported. ACU
initiates and tracks
volume expansion. After
volume expansion is
complete, the system
automatically
re-establishes
redundancy.