Hp StorageWorks EVA Controller HSG V8.8 Software Manual de usuario Pagina 62

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 150
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 61
Interpreting Agent Email Messages
62 Command Console V2.5 User Guide
0—Everything is fine.
1—Battery state went from bad to good.
2—Battery state went from good to bad.
The details of the battery failure follow in parentheses, in the format:
controller_id:state
where controller_id is the SCSI ID of the reporting controller (in other words,
the cache battery failed for the other controller), and
state is one of the
following:
Good—Battery is good.
Low—Battery voltage is low.
Fail—Battery has failed.
In this example, the cache battery for the controller with SCSI ID 6 failed.
The Sixth Digit of the State Change Field (Temperature)
The sixth digit of the state change field reports temperature state changes.
Example:
WARNING: -
Suncity HSG80 10000200000 HSG80 temp(0:2:2) (SP_MONITOR:
Monitor_Subsys)
The sixth digit can have one of three values:
0—Everything is fine.
1—Temperature state went from bad to good.
2—Temperature state went from good to bad.
The details regarding the temperature change follow in parentheses, in the format:
cabinet_number:sensor_type:state
where cabinet_number is the cabinet ID from 0-1, sensor_type is the EMU
sensor (sensor 1 or sensor 2), and
state is either of the following:
1—Temperature went from bad to good.
2—Temperature went from good to bad.
In this example, an adverse temperature change is detected by sensor 2 of the
main cabinet.
Vista de pagina 61