NOTE:
You must collect conguration data before collecting performance data for the rst time. You cannot stop
Conguration Data Collection once it is started.
Collecting conguration data
You can collect conguration data of an array either through the In Band or the Out Band mode. The in
band mode uses the Raid Manager Library (RMLib) to collect data of an a rray. The out band mode uses
the Remote Method Invocation (RMI) to collect data of the array from the SVP. Using the out band mode
ensures that the performance of SAN is not affected b ecause of data collection.
NOTE:
Conguration Data collection through out band mode is not supported for XP256/XP48/XP512 /
XP24000 arrays. You cannot collect conguration data for Continuous Access Journal through the out
band mode on XP12000K/XP10000 arrays. For details on the arrays supporting XP Thin Provisioning
(THP), Snapshot and Continuous Access Journal, see Appendix D.
NOTE:
To conguredatacollectiononaWindowssystem,seeAppendix C.
To star t collecting conguration data on a comma nd device, complete the following steps:
1. Select the command device(s), by selecting one or more rows from the list box for which you want
to collect data.
2. Select Collect C onguratio n Data.
3. Select In Band or Out Band.
In the in band mode, only one host can collect congura tion data per array.
In the out band mode, you must specify the IP address of the array in the Array IP Address box. You
cannotselectmultiplearraysintheoutbandmode.
4. Click Submit.
Conguration data collection starts on the selected command device.
NOTE:
Conguration changes made to the array are not automatically reected. You must perform conguration
data collection to get the latest conguration data.
NOTE:
Performance data collection schedules are based on the mode in which conguration data is collected. If
you have collected conguration data in the in band mode, the performance data collection schedules
are based on the in band mode. If you want to change the conguration data collection mode to out
band, you must delete the performance data collection schedules set and create new schedules for the