Hp XP Performance Advisor Software Manual de usuario Pagina 65

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 159
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 64
NOTE:
You have a choice to restart the conguration data collection before it has completed, if you are
collecting the data through the in band mode.
NOTE:
Performance Advisor reports only those XP Thin Provisioning and Snapshot volumes in an array that are
assigned to a pool. A Snapshot volume that is not assigned to a pool but has a path assigned from a
port, i s grouped under VVOL-Grp. For XP12000, all Snapshot volumes are grouped under Snap-Grp.
For more details, see Array View.
TIP:
Components 101
-16483 represent the external RAID group information, collected through the out
band mode.
Collecting performance data
If you select collecting performance data, you can perform the following functions:
Create/View schedule
Delete schedule
Start P erformance Data Collection
Stop Performance Da ta Collection
The following sections describe how to perform these functions:
Creating or viewing a performance data collection schedule
To create or view performance collection schedule, complete the following steps:
NOTE:
Performance data collection will not occur if the conguration data is being collected for any array.
1. Select the command device for which you want to create or view per formance data collection
schedule.
2. Select Collec t Performance Data in the Data Collection Conguration screen.
3. Select Create/View Sc h edule.
4. Click Submit. A new screen is displayed, as shown in Create/View Schedule.
HP StorageWorks Performance Advisor XP Software user guide
65
Vista de pagina 64
1 2 ... 60 61 62 63 64 65 66 67 68 69 70 ... 158 159