6. In the Apply Action drop-down menu, select Change Dispatch Sc hedule on Selected Items.
7. Click Apply Ac tion.
8. Click Commit/Refresh to save your changes to the database.
Disabling an alarm
To disable an alarm, complete the following steps:
1. Select the row(s) that you want to congure for the alarm(s) .
2. In the Apply Action drop-down menu, select Enable/Disable alarm on selected items.
3. Ensure that the Enable Alarm checkbox is not selected.
4. Click Apply
Action. An asterisk (*) in the Mod column indicates that modications are made to
the highlighted item.
5. Click Commit/Refresh to apply your changes to the database. No in the Ac tive column indicates that
the a larm is inactive.
Establishing scripts for alarms
Use scripts to p rovide executable les that assist you when alarm thresholds are crossed. For example,
you can write a script to run a query on performance data through the C LUI. To establish scripts for
alarms, complete the following steps:
1. Select the row(s) that you want to congure for the script.
2. In the Apply Action drop-down menu, select Change script le on selected items.
3. Enter the path name of the batch le in the Script le (XML) eld. For example: <?xml
version="1.0" ?> - <!-- A sample XML file describes the script to be
executed --> - <Service> <Method>Run Script</Method> - <!-- Enter the
full path name of your script file --> <Full-Script-Path>C:/Temp/
a.bat</Full-Script-Path> </Service>
4. Click Apply Ac tion.
5. Click Commit/Refresh to save your changes to the database. The location of the batch le appears
in the Script column in the list box.
Components of the Alarm Conguration screen
Table 22 lists the components that appear on the Alarm Conguration screen. Use these components to
congure alarm types.
Some elds may not be available. To enable the elds or checkboxes, click the associated buttons. For
example, the Dispatc h at Threshold Level eldmaynotbeavailableuntilyouclickChange dispatc h level
on se
lec ted items in the Apply Action drop-down menu.
Table 22 Alarm Conguration screen components
Comp
onent
Description
Abandon All Chan ges
Undo changes that you have made to th e items tha t
are highlighted. You must do this action before you
click Com mit/Refresh or the changes cannot be
reversed.
Add/Remove Alarm (button)
OpenstheAlarmConguration screen, where you
can create or remove alarms.
Apply Action (button)
Ap
plies changes that you have made to the items
hi
ghlighted.
HP StorageWorks Performance Advisor XP Software user guide
81
Vista de pagina 80
1 2 ... 76 77 78 79 80 81 82 83 84 85 86 ... 158 159