Scanner and cradle deep cleaning
IMPORTANT: Remove power before initiating the deep cleaning routine.
After completing the deep cleaning routine, allow the system to dry completely before reconnecting power.
Depending on the environmental conditions, wait at least 30 minutes or, if possible, leave the system
unpowered overnight.
If hard grime, grease, or liquid residue is present on electrical contacts, a deeper cleaning may be needed. If
the procedure above does not adequately clean the contacts for proper system operation, the use of
isopropyl alcohol is suggested (minimum 70%).
It is suggested that you use a cotton-tipped applicator with isopropyl alcohol, gently wiping along the pins of
the electrical connection. Be sure that cotton residue is not left on any pin of the electrical contacts.
Cleaning procedure 9