Chapter 8 Mounting the NetServer in a Rack
56
If you no longer have a template, place the rack nuts for the bezel
latch on the right front column in the 11th and 15th EIA holes above
the unit mounted below the HP NetServer. Place the rack nuts for the
bezel hinge on the left front column in the 6th and 19th EIA holes
above the unit mounted below the HP NetServer. See Figure 8-11.
2. Extend the slides fully until you hear a click, indicating they are in the
locked out position. Note that slides do not come apart. See Figure 8-12.
Figure 8-12. Fully Extend Slides and Anti-Tip Foot from Rack Front
Vista de pagina 63