Hp ProLiant DL385 G6 Server Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware De La Computadora Hp ProLiant DL385 G6 Server. HP ProLiant DL385 G6 Server User Manual [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 106
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
HP ProLiant DL385 G6 Server
User Guide
Part Number 575045-001
April 2009 (First Edition)
Vista de pagina 0
1 2 3 4 5 6 ... 105 106

Indice de contenidos

Pagina 1 - User Guide

HP ProLiant DL385 G6 Server User Guide Part Number 575045-001 April 2009 (First Edition)

Pagina 2 - Intended audience

Component identification 10 Rear panel components Item Description Color 1 PCI slot 5 — 2 PCI slot 6 — 3 PCI slot 4 — 4 PCI slot 2 — 5 P

Pagina 3 - Contents

Acronyms and abbreviations 100 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility AMP Advanced Memory Protection ASR A

Pagina 4 - Contents 4

Acronyms and abbreviations 101 iLO Integrated Lights-Out IML Integrated Management Log ISEE Instant Support Enterprise Edition NFPA National Fire

Pagina 5 - Contents 5

Acronyms and abbreviations 102 RDP Rapid Deployment Pack SAS serial attached SCSI SDRAM synchronous dynamic RAM SFF small form-factor SIM System

Pagina 6 - Contents 6

Index 103 A access panel 21, 22 ACU (Array Configuration Utility) 55 additional information 64 ADU (Array Diagnostic Utility) 61 air baffle

Pagina 7 - Component identification

Index 104 H hard drive bays 7 hard drive cable 52 hard drive LEDs 15 hard drives 15 hard drives, determining status of 15 hard drives, inst

Pagina 8 - Systems Insight Display LEDs

Index 105 power supply specfications 89 powering down 20 powering up 20, 54 power-on problems flowchart 71 pre-diagnostic steps 64 preparat

Pagina 9

Index 106 U UID LED 7, 11, 14 updating the system ROM 59 USB connectors 7, 10 USB support 59 utilities 53 utilities, deployment 53, 54, 5

Pagina 10 - Rear panel components

Component identification 11 Rear panel LEDs and buttons Item Description Status 1 Power supply 2 power LED Green = Normal Off = System is off or

Pagina 11 - Rear panel LEDs and buttons

Component identification 12 Notes: • "Primary" denotes the risers are installed in the primary riser connector. • "Secondary"

Pagina 12 - System board

Component identification 13 Item Description 10 System maintenance switch 11 Power supply backplane connector 12 Processor 1 socket 13 Primary r

Pagina 13 - System board switches

Component identification 14 Position Position Function On Off iLO 2 NMI functionality An NMI crash dump enables administrators to create crash dum

Pagina 14 - DIMM slots

Component identification 15 Hard drive numbering SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (g

Pagina 15 - SAS and SATA hard drive LEDs

Component identification 16 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Flashing regularly (1 Hz) Amber, flashing regularl

Pagina 16 - PCI riser cage LEDs

Component identification 17 Status On = AC power is connected. Off = AC power is disconnected. Missing = Riser is not installed and power mig

Pagina 17 - Battery pack LEDs

Component identification 18 LED3 pattern LED4 pattern Interpretation — One blink every two seconds The system is powered down, and the cache

Pagina 18 - Hot-plug fans

Component identification 19 For more information, see "Hot-plug fan operation (on page 26)."

Pagina 19 - Component identification 19

© Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Pagina 20 - Operations

Operations 20 Operations Power up the server To power up the server, press the Power On/Standby button. Power down the server WARNING: To reduce

Pagina 21 - Remove the access panel

Operations 21 3. After performing the installation or maintenance procedure, slide the server back into the rack, and then press the server firml

Pagina 22 - Remove the PCI riser cage

Operations 22 1. Power down the server if performing a non-hot-plug installation or maintenance procedure ("Power down the server" on page

Pagina 23 - Remove the air baffle

Operations 23 Install the PCI riser cage 1. Install the PCI riser cage. 2. Install the access panel (on page 22). 3. Install the server into the

Pagina 24

Operations 24 6. Remove the air baffle. Access the product rear panel Cable management arm with left-hand swing To access the server rear panel: 1.

Pagina 25

Operations 25 2. Open the cable management arm. Cable management arm with right-hand swing NOTE: To access some components, you may need to re

Pagina 26 - Hot-plug fan operation

Operations 26 Hot-plug fan operation CAUTION: To avoid damage to server components, fan blanks must be installed in fan bays 5 and 6 in a single-

Pagina 27 - Operations 27

Operations 27 CAUTION: A thermal event can damage server components when the Thermal Shutdown feature is disabled in RBSU.

Pagina 28 - Rack planning resources

Setup 28 Setup Optional installation services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and

Pagina 29 - Optimum environment

Setup 29 Optimum environment When installing the server in a rack, select a location that meets the environmental standards described in this section

Pagina 30 - Power requirements

Contents 3 Contents Component identification...

Pagina 31 - Rack warnings

Setup 30 Temperature requirements To ensure continued safe and reliable equipment operation, install or position the system in a well-ventilated, cli

Pagina 32 - Installing hardware options

Setup 31 Because of the high ground-leakage currents associated with multiple servers connected to the same power source, HP recommends the use of a

Pagina 33

Setup 32 Installing hardware options Install any hardware options before initializing the server. For options installation information, refer to the

Pagina 34 - Registering the server

Setup 33 18 iLO 2 connector — 19 NIC 3 connector — 20 NIC 4 connector — WARNING: To reduce the risk of electric shock, fire, or damage to

Pagina 35 - Processor option

Setup 34 WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding p

Pagina 36

Hardware options installation 35 Hardware options installation Introduction If more than one option is being installed, read the installation instruc

Pagina 37

Hardware options installation 36 6. Open the heatsink retaining bracket, and then remove the heatsink blank. CAUTION: The pins on the processor

Pagina 38

Hardware options installation 37 8. Rotate the latch and open the retaining bracket. IMPORTANT: Be sure the processor remains inside the process

Pagina 39

Hardware options installation 38 11. Press down firmly until the processor installation tool clicks and separates from the processor, and then re

Pagina 40 - Install the air baffle

Hardware options installation 39 12. Close the processor retaining bracket and the processor retaining latch. CAUTION: To prevent possible serve

Pagina 41

Contents 4 Powering up and configuring the server ...

Pagina 42

Hardware options installation 40 14. Install the heatsink. 15. Close the heatsink retaining bracket. 16. Install the air baffle.

Pagina 43

Hardware options installation 41 17. Remove the fan blanks in bays 5 and 6. 18. Install the fans into bays 5 and 6. 19. Install the PCI riser cag

Pagina 44 - Memory configurations

Hardware options installation 42 Enabling the TPM requires accessing the ROM-Based Setup Utility (RBSU) ("HP ROM-Based Setup Utility" on pa

Pagina 45 - Installing DIMMs

Hardware options installation 43 7. Install the TPM board. Press down on the connector to seat the board. 8. Install the TPM security rivet by pres

Pagina 46

Hardware options installation 44 • Always store the recovery key/password in multiple locations. • Always store copies of the recovery key/password

Pagina 47

Hardware options installation 45 o Menu Option 2 = 533 MHz — Memory bus speed is set to 533 MHz regardless of how many DIMMs are installed provided t

Pagina 48 - Expansion board options

Hardware options installation 46 7. Install the DIMM. 8. Install the air baffle ("Remove the air baffle" on page 23). 9. Install the PCI

Pagina 49

Hardware options installation 47 2. Prepare the hard drive. 3. Install the hard drive. 4. Determine the status of the hard drive from the hot-plu

Pagina 50

Hardware options installation 48 3. Remove the hard drive. Expansion board options The server supports PCI, PCI-X, and PCI Express expansion boards

Pagina 51 - PCI riser board option

Hardware options installation 49 o To remove slot covers 2 and 3, lift up on the latch, remove the latch, and then remove the cover. o To remove sl

Pagina 52 - Cabling

Contents 5 Change control and proactive notification ... 63 Care

Pagina 53 - Configuration and utilities

Hardware options installation 50 8. Install the PCI riser cage (on page 23). 9. Install the access panel (on page 22). Installing a full-length exp

Pagina 54 - HP ROM-Based Setup Utility

Hardware options installation 51 10. Connect any required internal or external cables to the expansion board. See the documentation that ships with t

Pagina 55 - Array Configuration Utility

Cabling 52 Cabling SAS hard drive cabling Battery cabling for BBWC

Pagina 56

Configuration and utilities 53 Configuration and utilities Configuration tools SmartStart software SmartStart is a collection of software that optim

Pagina 57 - Management tools

Configuration and utilities 54 Configuration Replication Utility CONREP is shipped in the SmartStart Scripting Toolkit and is a program that works w

Pagina 58 - Management Agents

Configuration and utilities 55 intervention. During this process, the ORCA utility, in most cases, automatically configures the array to a default s

Pagina 59 - Redundant ROM support

Configuration and utilities 56 • Supports online array capacity expansion, logical drive extension, assignment of online spares, and RAID or stripe

Pagina 60 - Diagnostic tools

Configuration and utilities 57 3. Select Serial Number. The following warning is displayed: WARNING! WARNING! WARNING! The serial number is loaded

Pagina 61 - Array Diagnostic Utility

Configuration and utilities 58 • Send alerts from iLO 2 regardless of the state of the host server. • Access advanced troubleshooting features thr

Pagina 62 - Keeping the system current

Configuration and utilities 59 Agents. For additional information, refer to the Management CD in the HP ProLiant Essentials Foundation Pack or the H

Pagina 63 - Care Pack

Contents 6 Customer Self Repair ...

Pagina 64 - Troubleshooting

Configuration and utilities 60 External USB functionality HP provides external USB support to enable local connection of USB devices for server admi

Pagina 65 - Warnings and cautions

Configuration and utilities 61 o For NetWare: IML Viewer o For Windows®: IML Viewer o For Linux: IML Viewer Application • From within the iLO 2 u

Pagina 66 - Symptom information

Configuration and utilities 62 Keeping the system current Drivers The server includes new hardware that may not have driver support on all operating

Pagina 67 - Loose connections

Configuration and utilities 63 To download the tool and for more information, see the HP website (http://www.hp.com/support). Change control and pr

Pagina 68 - Troubleshooting flowcharts

Troubleshooting 64 Troubleshooting Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common p

Pagina 69 - General diagnosis flowchart

Troubleshooting 65 Important safety information Before servicing this product, read the Important Safety Information document provided with the se

Pagina 70 - Item Refer to

Troubleshooting 66 WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling feet are extended to th

Pagina 71 - Symptoms:

Troubleshooting 67 To answer these questions, the following information may be useful: • Run HP Insight Diagnostics (on page 60) and use the survey

Pagina 72

Troubleshooting 68 • If a device has latches, be sure they are completely closed and locked. • Check any interlock or interconnect LEDs that may in

Pagina 73 - Troubleshooting 73

Troubleshooting 69 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of

Pagina 74 - POST problems flowchart

Component identification 7 Component identification Front panel components Item Description 1 Serial number label 2 Systems Insight Display 3

Pagina 75 - OS boot problems flowchart

Troubleshooting 70 Item Refer to 5 "General memory problems are occurring" in the HP ProLiant Servers Troubleshooting Guide located on the

Pagina 76

Troubleshooting 71 Server power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber.

Pagina 77

Troubleshooting 72 • The external health LED is red or amber. • The internal health LED is red or amber. NOTE: For the location of server LEDs

Pagina 79 - Troubleshooting 79

Troubleshooting 74 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system atte

Pagina 80 - System battery

Troubleshooting 75 OS boot problems flowchart Symptoms: • Server does not boot a previously installed operating system • Server does not boot Sma

Pagina 81 - Class B equipment

Troubleshooting 76 Item Refer to 1 HP ROM-Based Setup Utility User Guide (http://www.hp.com/servers/smartstart) 2 "POST problems flowchart

Pagina 82 - Modifications

Troubleshooting 77 Server fault indications flowchart Symptoms: • Server boots, but a fault event is reported by Insight Management Agents (on pag

Pagina 83 - • EMC Directive 2004/108/EC

Troubleshooting 78 NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation. Possible causes:

Pagina 84 - Korean notice

Troubleshooting 79 POST error messages and beep codes For a complete listing of error messages, refer to the "POST error messages" in the

Pagina 85 - Battery replacement notice

Component identification 8 Item Description Status 1 UID LED button Blue = Activated Flashing blue = System being remotely managed Off = Deact

Pagina 86

System battery 80 System battery If the server no longer automatically displays the correct date and time, you may need to replace the battery that

Pagina 87 - Electrostatic discharge

Regulatory compliance notices 81 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance

Pagina 88 - Specifications

Regulatory compliance notices 82 energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio

Pagina 89 - Power supply specifications

Regulatory compliance notices 83 Canadian notice (Avis Canadien) Class A equipment This Class A digital apparatus meets all requirements of the Cana

Pagina 90

Regulatory compliance notices 84 This symbol on the product or on its packaging indicates that this product must not be disposed of with your other

Pagina 91

Regulatory compliance notices 85 Class B equipment Chinese notice Class A equipment Laser compliance This product may be provided with an optica

Pagina 92 - Technical support

Regulatory compliance notices 86 Batteries, battery packs, and accumulators should not be disposed of together with the general household waste.

Pagina 93 - Technical support 93

Electrostatic discharge 87 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Pagina 94 - Customer Self Repair

Specifications 88 Specifications Environmental specifications Specification Value Temperature range* Operating 10°C to 35°C (50°F to 95°F) Shippi

Pagina 95 - Technical support 95

Specifications 89 BTUs per hour 2285 at 100V to 120V AC input 2217 at 200V to 240V AC input Power supply output Rated steady-state power For more

Pagina 96 - Reparo feito pelo cliente

Component identification 9 Systems Insight Display LEDs and internal health LED combinations When the internal health LED on the front panel illumin

Pagina 97 - Technical support 97

Specifications 90 • HP ProLiant 750 W Power Supply Specification Value Input requirements Rated input voltage 100V to 120V AC 200V to 240V AC Rat

Pagina 98 - Technical support 98

Specifications 91 Rated peak power 800 W at 100V AC input 900 W at 120V AC input 1200 W at 200V to 240V AC input • HP ProLiant 1200 W DC Power Sup

Pagina 99 - Technical support 99

Technical support 92 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical su

Pagina 100 - Acronyms and abbreviations

Technical support 93 • Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, howev

Pagina 101

Technical support 94 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'informations

Pagina 102

Technical support 95 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen, muss das

Pagina 103 - Index 103

Technical support 96 el caso de todas sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de compo

Pagina 104 - Index 104

Technical support 97 • Obrigatória – Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas

Pagina 105 - Index 105

Technical support 98

Pagina 106 - Index 106

Technical support 99

Comentarios a estos manuales

Sin comentarios