Hardware options installation 75
10.
Using a T-15 Torx screwdriver, remove the screws from the blank and install them on the device.
11. Slide the media device part of the way into the bay.
12. Connect the server data and power cables to the rear of the device.
13. Slide the media drive fully into the bay until it is seated securely.
14. Install the fan cage.
15. Install the air baffle.
16. If removed, install the BBWC battery pack or the FBWC capacitor pack ("Installing the BBWC battery
pack or the FBWC capacitor pack" on page 86).
17. Install fan 5.
18. Install the access panel.
19. Do one of the following:
o Close or install the tower bezel, as needed.
o Slide the server back into the rack.