Hardware options installation 53
9.
Route the cable through the air baffle, and then connect the cable to the connector on the adapter
board.
10. Install the 2U adapter board bracket (on page 23).
11. Install the PCI riser cage (on page 21).
12. Install the node into the chassis ("Installing a node into the chassis" on page 30).
13. Connect all peripheral cables to the node.
14. Power up the node ("Power up the nodes" on page 17).
Installing the Mini-SAS P830 cable in a 2U node
1. Power down the node (on page 17).
2. Disconnect all peripheral cables.
3. Remove the node from the chassis (on page 17).
4. Remove the PCI riser cage (on page 20).
5. Remove the 2U adapter board bracket (on page 22).
6. Disconnect and remove the Mini-SAS cable ("Remove the Mini-SAS cable" on page 23).
7. If not installed, install a P830 Smart Array controller into the PCI riser cage ("Installing an expansion
board" on page 42).
8. Connect the Mini-SAS Y-cables:
a. Connect the Mini-SAS Y-cable x8 connectors to the P830 Smart Array controller.
b. Route the right-angle cable through the air baffle, and then connect the two ends of the cable to the
corresponding connectors on the bottom adapter board.
c. Install the 2U adapter board bracket (on page 23).