I
-
I
-
Using Spectrum Analyzer Features
Using limit-line Functions
Limit-Line
Functions
This section describes the limit-line functions in the order that they are
usually used.
Editing, Creating, or
Viewing a Limit-Line
Pressing
(m),
then Limit Lines accesses the softkey menus used for
creating a limit line.
Press Edit Limit to edit an existing limit-line table or. If no limit-line table
currently exists this will allow you to create one.
If a limit line exists currently, and you would like to purge it and
create a new one, press Edit Upper , and Mare 1 of 2 . Then press
PURGE LIMITS two times to clear the existing limit-line table and access the
limit-line editing menu.
NOTE
After pressing PURGE LIMITS the first time, the message If you are sure, press
key again to purge data will appear. Pressing PURGE LIMITS a second time
purges the limit-line table.
@%iZFi)
turns limit-line testing off
lif
it is onl, but does not clear an
existing limit-line table.