Making Basic Measurements Using Spectrum Analyzer Mode
Using the Analyzer As a Receiver in Zero Frequency Span
Example: View the modulation waveform of an AM signal in the time
domain.
1. To obtain an AM signal, you can either connect an antenna to the
spectrum analyzer input and tune to a commercial AM broadcast station
or you can connect a source to the spectrum analyzer input and set the
percent modulation of the source. (If a headset is used with the VIDEO
OUT connector, the spectrum analyzer will operate as a radio.)
2. First, center and zoom in on the signal in the frequency domain. (See
“Decreasing the Frequency Span Using the Marker Track Function.
“)
Be
sure to turn off the marker track function, since the marker track function
must be off for zero span. See Figure 4-25.
NEXT
PEAK
SPAN
200.0
kHZ
30
“BW
30 bHL
XSWP
20
0
Figure 4-25. Viewing an AM Signal
4-38