Troubleshooting HyperFabric
LED Colors and Their Meanings
Chapter 5
119
For each port on the cards/switch module in the switch:
If the port is not operational, the LED is off. Some of the possible reasons for this
happening are the following:
A cable is not attached correctly to the port or no cable is attached at all.
The port is connected to a non-operational adapter in an HP 9000. (See
Adapter LEDs on page 111 or Table 5-2 on page 113 for some tips about a
non-operational adapter.)
The cable is bad.
The port is bad. Note that if a port is bad, and (for some reason) you cannot
use a different port on that card/switch module, you can replace the
card/switch module. Remember, though, that the integrated 8-port fibre card
can be removed by qualified Hewlett-Packard personnel only. The A6388A
and A6389A switch modules can be removed by you or qualified
Hewlett-Packard personnel. However, you first should try turning the
switchs power off and then back on.
If the connection from the port to the corresponding adapter in the HP 9000 is
operational, the LED on the port shows as solid green.
If data is flowing between the port and the corresponding adapter, the LED
shows as flashing green. Note that data does not start to flow until HyperFabric
initialization has occurred (see Using the clic_init Command on page 92).
Note that a legend listing the possible port statesdisconnected, connected, and
trafficand the corresponding LED colors is printed on the front of the switch, for
your reference.