HP HyperFabric Manual de instalación Pagina 148

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 147
Troubleshooting HyperFabric
Determining Whether a Switch is Faulty
Chapter 5
124
a. If the port is connected to an operational Ethernet network, the ports LED
(Ethernet Port Main or Ethernet Port Aux) shows as solid or blinking green.
b. If the port is disconnected, or connected to an Ethernet network that is not
operational, the ports LED is off.
Step 4. Check the ports on the cards/switch module:
a. Disconnect the cable from the card/switch module port you suspect is faulty.
b. Attach a loopback plug to the relevant port:
If the port is on the integrated 8-port fibre card or the A6388A HF2 8-port fibre
switch module in the expansion slot, use a fibre loopback plug. (A fibre loopback
plug [HP part number A6384-67004] is shipped with each HF2 switch).
If the port is on the A6389A HF2 4-port copper switch module in the expansion
slot, use a copper loopback plug (one is shipped with each HF1 adapter).
c. Determine if the port is faulty:
If the port is functioning correctly, the Port x LED shows as solid or blinking
green.
If the port is faulty, the Port x LED is off.
Repeat steps a through c for each port on the cards/switch module, to determine if
any of them are faulty.
d. If the port is faulty, do not use it. Instead, use a known good port on that card/switch
module if one is available. If no good ports are available, replace that card/switch
module. Remember, though, that the integrated 8-port fibre card can be removed by
qualified Hewlett-Packard personnel only. The A6388A and A6389A switch modules
can be removed by you or qualified Hewlett-Packard personnel.
Step 5. If a fan is not running, the fan tray must be replaced by qualified Hewlett-Packard
personnel only.
Vista de pagina 147

Comentarios a estos manuales

Sin comentarios