HP 24S Guía de usuario Pagina 51

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 102
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 50
Testing the Hub’s Ports and the Links
To test the hub’s ports and the attached network links, choose one of the following ways to
run a test between the hub and an addressable device connected at the remote end of each
of the cables you wish to test:
Use the console’s Testlink command to run a link test. This works with devices
able to send an IEEE 802.2 Test response packet upon receipt of a Test command
packet. You specify the remote device by its 12-digit hexadecimal station address.
See “Testlink” in chapter 3 for details.
For the HP 28688B and HP 28699A only, use the console’s Ping command to run a
network-layer test. This works with devices having an IP address and which are
able to respond to an ICMP echo request packet. You specify the remote device by
its IP address. See “Ping” in chapter 3 for details.
For the HP 28688B and HP 28699A only, use HP network management software
to test the link. For instructions, see the network management product’s
documentation.
If the test passes, the hub’s port, the network link, and the remote device are all working
properly. If testing the AUI port, this also tests a transceiver that is connected to the port.
If the test fails, you can test the hub using the procedures on the previous page. You
should also verify that the remote device is powered on and functioning properly, and that
the cable is good.
Testing Twisted-Pair Cabling
Twisted-pair cable must be compatible with the IEEE 802.3 Type 10Base-T standard.
Instruments are available that you can use to verify that your cable is compatible with
this standard. One such instrument is the HP 28687A Wire Test Instrument. HP also
offers a wire testing service. Contact your local HP sales office for more information.
Troubleshooting 4-5
Vista de pagina 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 101 102

Comentarios a estos manuales

Sin comentarios