To access the configuration mode of the Model 24SII DES, use the
following procedure:
1. Connect a dumb terminal (or a PC running a terminal
emulation program) to the master configuration port
(Port 1 of Module 1) or to any serial computer port.
Configure your terminal's serial parameters to match
those of the Model 24SII DES. From the factory, all
serial ports on the Model 24SII DES are factory set at
9600 baud rate, 8 word size, 1 stop bit, no parity, and
XON/XOFF disabled.
If you do not have a dumb terminal or a terminal
emulation program, BayTech supplies a utility diskette
which includes software to put an IBM PC or compatible
into a terminal mode. See
Section 4.2
for instructions to
obtain the software (TERM.EXE) and
Section 4.6
for
instructions to use TERM for configuration.
2. Send from this device to the Model 24SII DES port being
used for configuration the following control characters:
ASCII Control-T (14 Hex), ASCII capital C (43 Hex),
and the desired module number (1 to 6).
For example, if your terminal is connected to Port 1 of Module
1 and you wish to configure a port on Module 1, you would
send the following: <Control-T>C1.