Server Error Messages C-3
Compaq Confidential Need to Know Required
Writer: CDresden Project: Compaq ProLiant ML370 Generation 2 Server Setup and Installation Guide Comments: Graphics Replaced
Part Number: 203510-001 File Name: n-appc Server Error Messages-J.doc Last Saved On: 7/12/01 11:18 AM
Table C-1
POST Error Messages
continued
Error Code Audible Beeps Probable Source
of Problem
Action
209-Online Spare
Memory
Configuration Bank
C is Invalid or By
Itself.
1 long, 1 short Bank C not
populated or only
populated bank
Verify the size and speed of the
memory modules installed, then
check your server user
documentation and replace as
indicated.
1611- Fan X failure
detected.
2 short Fan failure Replace the failed fan.
1611-Fan X not
present
2 short Fan not installed or
not seated
Reseat or install a fan in position X.