Message ID Message Text Explanation
KAPL09281-I HDLM 6.3.0 or later has been
installed. Only the HDLM driver
will be installed, without
overwriting the MPIO driver.
Details
The MPIO driver will not be
installed because the version of
the installed MPIO driver is the
same as the one bundled with
HDLM.
Action
None.
If you want to re-install the MPIO
driver bundled with HDLM, select
the [Re-install MPIO driver] check
box.
KAPL09283-W A silent installation cannot be
executed by using aa...aa\bin
\installhdlm.exe.
To execute a silent installation,
use the HDLM installation utility
(installhdlm) that is included on
the installation media.
Details
A silent installation cannot be
executed by using HDLM-
installation-folder\bin
\installhdlm.exe.
aa...aa: HDLM installation folder
Action
To execute a silent installation,
use drive-to-which-the-
installation-DVD-is-inserted:
\HDLM_Windows\DLMTools
\installhdlm.exe.
KAPL09284-W HDLM is not installed. Details
If HDLM is not installed, the
installhdlm utility for installing
HDLM cannot be executed with
the -v parameter.
Action
None.
KAPL09287-W The HDLM for VMware has
already been installed in this
system.
Details
HDLM for Windows and HDLM for
VMware cannot be installed on the
same host.
Action
None.
KAPL09501-E HDLM is not installed on this
system.
Details
An SP cannot be applied because
HDLM is not installed on the
system.
Action
Check whether HDLM has been
correctly installed.
KAPL09504-E The language environments of
HDLM and the Service Pack are
different.
Details
8-78
Messages
Hitachi Dynamic Link Manager User Guide (for Windows(R))
Vista de pagina 359