For proper installation of the power supplies into a compute enclosure, see the HP Integrity
Superdome 2 Installation Guide.
Power and Thermal screen
DescriptionItem
This box displays the highest ambient temperature being
reported by the installed blade devices. If no blade devices
Enclosure Ambient Temperature
are installed, then this box displays the temperature of the
Onboard Administrator module as an approximation of
the ambient temperature.
The overall thermal status of the enclosure. Possible values
are Unknown, OK, Degraded, or Critical Error.
Thermal Subsystem Status
The overall power status of the enclosure. Possible values
are Unknown, OK, Degraded, or Critical Error.
Power Subsystem Status
A user setting to configure the enclosure dc power capacity
and the input power redundancy mode of the enclosure.
See Power Management for possible values.
Power Mode
The amount of watts being consumed by all devices in the
enclosure.
Present Power
The maximum amount of power available for consumption
by the enclosure measured in watts.
Power Limit
NOTE: The Power Limit is dependent on the enclosure power redundancy setting and the number
and location of the power supplies in the enclosure. If a Static Power Limit has been specified, the
Power Limit displays that limit.
130 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices