• Restrictions:
You must have access to the specified bay number.
• Example:
OA-0018FE27577F> SHOW SERVER POWERDELAY ALL
Current PowerDelay Status: Not in Progress
Bay Device PowerDelay State Delay (seconds)
--- -------------------------------- ------------
1 Absent Disabled
1A Absent Disabled
1B Absent Disabled
2 Subsumed Disabled
2A ProLiant BL2x220c G5 Disabled
2B ProLiant BL2x220c G5 Disabled
3 Absent Disabled
3A Absent Disabled
3B Absent Disabled
4 Absent Disabled
4A Absent Disabled
4B Absent Disabled
5 Absent Disabled
5A Absent Disabled
5B Absent Disabled
6 Absent Disabled
6A Absent Disabled
6B Absent Disabled
7 ProLiant BL460c G1 Disabled
7A Absent Disabled
7B Absent Disabled
8 AiO SB600c Storage Disabled
8A Absent Disabled
8B Absent Disabled
SHOW BLADE STATUS
• Command:
SHOW BLADE STATUS {ALL | <bay number> [{ , | - } <bay number>]}
NOTE: SERVER is a valid alias for BLADE.
• Description:
Displays the following settings of server blade:
◦ Power (OK or off)
◦ Health (OK, CPU failure, or power module failure)
◦ Thermal (OK, warm, caution, or critical)
◦ UID LED
102 Blade management commands