Hp Integrity Superdome 2 Server Manual de usuario Pagina 102

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 217
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 101
Restrictions:
You must have access to the specified bay number.
Example:
OA-0018FE27577F> SHOW SERVER POWERDELAY ALL
Current PowerDelay Status: Not in Progress
Bay Device PowerDelay State Delay (seconds)
--- -------------------------------- ------------
1 Absent Disabled
1A Absent Disabled
1B Absent Disabled
2 Subsumed Disabled
2A ProLiant BL2x220c G5 Disabled
2B ProLiant BL2x220c G5 Disabled
3 Absent Disabled
3A Absent Disabled
3B Absent Disabled
4 Absent Disabled
4A Absent Disabled
4B Absent Disabled
5 Absent Disabled
5A Absent Disabled
5B Absent Disabled
6 Absent Disabled
6A Absent Disabled
6B Absent Disabled
7 ProLiant BL460c G1 Disabled
7A Absent Disabled
7B Absent Disabled
8 AiO SB600c Storage Disabled
8A Absent Disabled
8B Absent Disabled
SHOW BLADE STATUS
Command:
SHOW BLADE STATUS {ALL | <bay number> [{ , | - } <bay number>]}
NOTE: SERVER is a valid alias for BLADE.
Description:
Displays the following settings of server blade:
Power (OK or off)
Health (OK, CPU failure, or power module failure)
Thermal (OK, warm, caution, or critical)
UID LED
102 Blade management commands