Hp ProLiant DL360p Gen8 Server Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware De La Computadora Hp ProLiant DL360p Gen8 Server. HP ProLiant DL360p Gen8 Server User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 118
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
HP ProLiant DL360p Gen8 Server
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 664724-006
February 2014
Edition: 6
Vista de pagina 0
1 2 3 4 5 6 ... 117 118

Indice de contenidos

Pagina 1 - User Guide

HP ProLiant DL360p Gen8 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage

Pagina 2

Component identification 10 • 10 SFF Item Description Status 1 UID button/LED Solid blue = Activated Flashing blue (1 Hz/cycle per sec) = Remo

Pagina 3 - Contents

Specifications 100 Rated input voltage 100 to 120 VAC, 200 to 240 VAC Rated input frequency 50 Hz to 60 Hz Rated input current 8.9 A at 100 VAC 4.3

Pagina 4 - Contents 4

Specifications 101 4.1 A at 200 VAC Maximum rated input power 843 W at 100V AC input 811 W at 200V AC input Btus per hour 2878 at 100V AC input 2769

Pagina 5 - Contents 5

Specifications 102 DC source and the point of connection of the earthing electrode conductor. CAUTION: To reduce the risk of electric shock or

Pagina 6

Support and other resources 103 Support and other resources Before you contact HP Be sure to have the following information available before you cal

Pagina 7 - Component identification

Support and other resources 104 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Pagina 8 - • 10 SFF

Support and other resources 105 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'i

Pagina 9 - Front panel LEDs and buttons

Support and other resources 106 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen

Pagina 10 - Rear panel components

Support and other resources 107 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Pagina 11 - Rear panel LEDs and buttons

Support and other resources 108 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pe

Pagina 12 - System board components

Support and other resources 109

Pagina 13 - DIMM slots

Component identification 11 Item Description 1 Slot 2 PCIe 3.0 x16 (full height/half length) 2 FlexibleLOM ports (Shown: 4x1Gb / Optional: 2x10Gb

Pagina 14 - NMI jumper

Support and other resources 110

Pagina 15 - Systems Insight Display LEDs

Acronyms and abbreviations 111 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility AMP Advanced Memory Protection ASR A

Pagina 16

Acronyms and abbreviations 112 LFF large form factor LRDIMM load reduced dual in-line memory module NMI nonmaskable interrupt NVRAM nonvolatile m

Pagina 17 - Device numbers

Acronyms and abbreviations 113 SELV separated extra low voltage SFF small form factor SSA HP Smart Storage Administrator TMRA recommended ambient

Pagina 18 - Fan modules

Documentation feedback 114 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documenta

Pagina 19 - Component identification 19

Index 115 A AC power supply 97, 98, 99, 100, 102 access panel 23 Active Health System 78, 79 ACU (Array Configuration Utility) 78, 85, 86 Ad

Pagina 20 - Operations

Index 116 front panel components 7 front panel LEDs 9 front video adapter 58 G grounding methods 95 grounding requirements 29 H hard drive

Pagina 21

Index 117 power supply bays 10 power supply LEDs 15 power supply specifications 97, 98, 99, 100, 101, 102 powering down 20 powering up 20

Pagina 22 - 10 SFF configuration

Index 118 USB support 87 utilities 78, 85 utilities, deployment 78, 82, 83 V ventilation 27 Version Control Agent (VCA) 88 Version Control

Pagina 23 - Install the access panel

Component identification 12 Item Description Status • AC power unavailable • Power supply failed • Power supply in standby mode • Power supply

Pagina 24 - Remove the PCI riser cage

Component identification 13 Item Description 8 SAS connector B (Drives 5–8) 9 SAS connector A (drives 1–4) 10 NMI jumper 11 System maintenance swit

Pagina 25 - Install the PCI riser cage

Component identification 14 System maintenance switch Position Default Function S1 Off Off = HP iLO security is enabled. On = HP iLO security is

Pagina 26

Component identification 15 Systems Insight Display LEDs The HP Systems Insight Display LEDs represent the system board layout. The display provides

Pagina 27 - Optimum environment

Component identification 16 Systems Insight Display LED combinations When the health LED on the front panel illuminates either amber or red, the ser

Pagina 28 - Temperature requirements

Component identification 17 Device numbers • 4 LFF configuration • 8 SFF configuration • 10 SFF configuration IMPORTANT: A cache module is

Pagina 29 - Power requirements

Component identification 18 Hot-plug drive LED definitions Item LED Status Definition 1 Locate Solid blue The drive is being identified b

Pagina 30 - Rack warnings

Component identification 19 When only one processor is installed, be sure the fan blanks are always installed in bays 1 and 2 to ensure proper cooli

Pagina 31 - Installing hardware options

© Copyright 2012, 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only war

Pagina 32

Operations 20 Operations Power up the server To power up the server, press the Power On/Standby button. Power down the server Before powering down

Pagina 33

Operations 21 WARNING: To reduce the risk of personal injury, be careful when pressing the server rail-release latches and sliding the server into

Pagina 34 - Registering the server

Operations 22 The display can be rotated up to 90 degrees. o 10 SFF configuration

Pagina 35 - Introduction

Operations 23 The display can be rotated up to 90 degrees. Remove the access panel WARNING: To reduce the risk of personal injury from hot sur

Pagina 36 - Screw-down heatsink blank

Operations 24 b. Disconnect each power cord from the server. 3. Extend the server from the rack (on page 20). 4. Remove the access panel (on page

Pagina 37

Operations 25 The server may look different than the one shown in the following illustration, depending on the server model. Install the PCI riser

Pagina 38

Operations 26 The server may look different than the one shown in the following illustration, depending on the server model. 8. Install the access

Pagina 39

Setup 27 Setup Support and deployment services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up an

Pagina 40 - Screw-down heatsink

Setup 28 • Leave a minimum clearance of 63.5 cm (25 in) in front of the rack. • Leave a minimum clearance of 76.2 cm (30 in) behind the rack. • L

Pagina 41

Setup 29 Power requirements Installation of this equipment must comply with local and regional electrical regulations governing the installation of

Pagina 42 - Memory options

Contents 3 Contents Introduction ...

Pagina 43

Setup 30 WARNING: To reduce the risk of electric shock or energy hazards: • This equipment must be installed by trained service personnel, as def

Pagina 44 - HP SmartMemory

Setup 31 WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are extended to the floor.

Pagina 45

Setup 32 WARNING: This server is very heavy. To reduce the risk of personal injury or damage to the equipment: • Observe local occupational healt

Pagina 46 - Memory configurations

Setup 33 4. Use the strain relief clip from the server hardware kit to secure the power cord. 5. Connect the power cord to the power source. Powe

Pagina 47

Setup 34 Provisioning can configure the server and install an operating system, eliminating the need for SmartStart CDs and Smart Update Firmware DV

Pagina 48 - Online spare population

Hardware options installation 35 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Pagina 49 - Installing a DIMM

Hardware options installation 36 6. Remove the heatsink blank: o Caged heatsink blank o Screw-down heatsink blank

Pagina 50

Hardware options installation 37 7. Open each of the processor locking levers in the order indicated, and then open the processor retaining bracket.

Pagina 51 - 2. Prepare the drive

Hardware options installation 38 9. Install the processor. Verify that the processor is fully seated in the processor retaining bracket by visually

Pagina 52

Hardware options installation 39 11. Press and hold the processor retaining bracket in place, and then close each processor locking lever. Press onl

Pagina 53

Contents 4 Processor and fan module option ...

Pagina 54

Hardware options installation 40 o Caged heatsink o Screw-down heatsink

Pagina 55

Hardware options installation 41 14. Remove the fan blanks. 15. Install the fans: CAUTION: To avoid thermal shutdown, all fans must be install

Pagina 56 - Controller options

Hardware options installation 42 b. Secure the locking latches. o For fans without latches, install the fans into slots 1 and 2. 16. Install the

Pagina 57

Hardware options installation 43 • UDIMMs represent the most basic type of memory module and offer lower latency in one DIMM per channel configurat

Pagina 58 - Front video adapter option

Hardware options installation 44 DIMM type DIMM rank 1 DIMM per channel 2 DIMMs per channel 3 DIMMs per channel RDIMM Dual-rank (8 GB) 1333 1

Pagina 59 - FlexibleLOM option

Hardware options installation 45 Channel Population order Slot number 2 B F J 9 8 7 3 C G K 1 2 3 4 D H L 4 5 6 For the location of the slot numb

Pagina 60

Hardware options installation 46 DIMM identification To determine DIMM characteristics, use the label attached to the DIMM and the following illustr

Pagina 61 - Expansion board option

Hardware options installation 47 • Online spare memory—provides protection against failing or degraded DIMMs. Certain memory is reserved as spare,

Pagina 62

Hardware options installation 48 Lockstep memory configuration Lockstep mode provides protection against multi-bit memory errors that occur on the s

Pagina 63

Hardware options installation 49 o LRDIMMs are treated as dual-rank DIMMs. Lockstep Memory population guidelines For Lockstep memory mode configura

Pagina 64 - 48V DC power supply option

Contents 5 ROMPaq utility ...

Pagina 65

Hardware options installation 50 6. Install the DIMM. 7. Install the access panel (on page 23). 8. Slide the server into the rack. 9. Connect ea

Pagina 66

Hardware options installation 51 Removing the hard drive blank Remove the component as indicated. Installing a hot-plug hard drive The server can

Pagina 67 - Replace the safety cover

Hardware options installation 52 3. Install the drive. 4. Determine the status of the drive from the drive LED definitions ("Hot-plug drive L

Pagina 68 - Rack bezel option

Hardware options installation 53 5. Remove the bezel blank from the DVD-ROM bay. 6. For an SFF DVD drive, do the following: The server may look di

Pagina 69

Hardware options installation 54 b. Connect the cable to the rear of the drive and to the SATA DVD-ROM drive connector on the system board. c. Cli

Pagina 70

Hardware options installation 55 a. Connect the cable to the rear of the DVD drive, and then route the cable through the DVD drive bay. b. Install

Pagina 71

Hardware options installation 56 Controller options The server ships with an embedded Smart Array P420i controller. For more information about the s

Pagina 72 - Cabling

Hardware options installation 57 To install the component: 1. Power down the server (on page 20). 2. Remove all power: a. Disconnect each power c

Pagina 73 - Chipset SATA cable option

Hardware options installation 58 CAUTION: When connecting or disconnecting the capacitor pack cable, the connectors on the cache module and cable

Pagina 74

Hardware options installation 59 2. Connect the front video adapter to the video device. To remove the front video adapter, squeeze the top and

Pagina 75 - Cabling 75

Introduction 6 Introduction Server features The HP ProLiant DL360p Gen8 SE Server comes with industry leading performance, efficiency, capacity, and

Pagina 76

Hardware options installation 60 3. Remove any attached network cables. 4. Extend the server from the rack (on page 20). 5. Remove the access pane

Pagina 77 - FBWC capacitor pack cabling

Hardware options installation 61 7. Power up the server (on page 20). Expansion board option The server ships with PCIe riser boards and expansion

Pagina 78 - HP iLO Management

Hardware options installation 62 Redundant hot-plug power supply option CAUTION: All power supplies installed in the server must have the same o

Pagina 79 - Active Health System

Hardware options installation 63 3. Remove the protective cover from the connector pins on the power supply. WARNING: To reduce the risk of ele

Pagina 80 - Intelligent Provisioning

Hardware options installation 64 5. Connect the power cord to the power supply. 6. Route the power cord through the cable management solution. 7.

Pagina 81 - Erase Utility

Hardware options installation 65 2. If you are not using an optional HP input cable, with the ground cable disconnected from the 48V power source, c

Pagina 82 - HP Service Pack for ProLiant

Hardware options installation 66 5. Attach the ground (earthed) wire to the ground screw and washer and tighten to 1.47 N m (13 lb-in) of torque

Pagina 83 - HP ROM-Based Setup Utility

Hardware options installation 67 6. Attach the power ring tongues to the terminal block, following the polarity label below the terminal block, and

Pagina 84 - Configuring AMP modes

Hardware options installation 68 8. Insert the power supply into the power supply bay until it clicks into place. 9. Route the power cord. Use bes

Pagina 85 - Utilities and features

Hardware options installation 69 HP Trusted Platform Module option For more information about product features, specifications, options, configurati

Pagina 86

Component identification 7 Component identification Front panel components • 8 SFF Item Description 1 SAS/SATA/SSD drive bay 1 2 SAS/SATA/SSD d

Pagina 87 - Redundant ROM support

Hardware options installation 70 a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Remove the

Pagina 88 - Keeping the system current

Hardware options installation 71 11. Install the server into the rack ("Installing the server into the rack" on page 31). 12. Connect eac

Pagina 89 - ProLiant servers

Cabling 72 Cabling Cabling overview This section provides guidelines that help you make informed decisions about cabling the server and hardware opt

Pagina 90 - Troubleshooting

Cabling 73 • LFF DVD-ROM and DVD-RW drive cabling The server may look different than the one shown in the following illustration, depending on th

Pagina 91 - System battery

Cabling 74 o The optical bay is disabled because the chipset SATA controller port on the system board is redirected from the optical bay to the driv

Pagina 92 - System battery 92

Cabling 75 The server may look different than the one shown in the following illustrations, depending on the server model. 6. Disconnect the SATA

Pagina 93 - Regulatory information

Cabling 76 b. Connect the remaining chipset SATA cable connector to the SATA header on the hard drive cage. 8. Clip the cable to the power supply

Pagina 94 - Warranty information

Cabling 77 FBWC capacitor pack cabling The second (left) capacitor pack cable connects to an optional Smart Array expansion board.

Pagina 95 - Electrostatic discharge

Software and configuration utilities 78 Software and configuration utilities Server mode The software and configuration utilities presented in this

Pagina 96 - Specifications

Software and configuration utilities 79 HP iLO enables and manages the Active Health System (on page 79) and also features Agentless Management. All

Pagina 97

Component identification 8 • 4 LFF Item Description 1 SAS/SATA/SSD drive bay 1 2 DVD-ROM drive (optional) 3 SAS/SATA/SSD drive bay 2 4 Serial nu

Pagina 98

Software and configuration utilities 80 The data that is collected is managed according to the HP Data Privacy policy. For more information see the

Pagina 99

Software and configuration utilities 81 see the Resources tab on the HP website (http://www.hp.com/go/ilo). For consolidated drive and firmware upda

Pagina 100 - (94% efficiency)

Software and configuration utilities 82 HP Insight Remote Support software HP strongly recommends that you register your device for remote support t

Pagina 101

Software and configuration utilities 83 To download HP SUM, see the HP website (http://www.hp.com/go/hpsum/download). To access the HP Smart Update

Pagina 102

Software and configuration utilities 84 NOTE: The server may not support all the following examples. Drives installed Drives used RAID

Pagina 103 - Support and other resources

Software and configuration utilities 85 Warning: The serial number should ONLY be modified by qualified service personnel. This value should always

Pagina 104

Software and configuration utilities 86 • If an optional controller is installed, when the system recognizes the controller during POST, press F5.

Pagina 105 - Customer Self Repair

Software and configuration utilities 87 For more information about the storage controller and its features, select the relevant controller user docu

Pagina 106

Software and configuration utilities 88 NOTE: The server ships with the same version programmed on each side of the ROM. Safety and security b

Pagina 107 - Reparo feito pelo cliente

Software and configuration utilities 89 • VCRM manages the repository for SPP. Administrators can view the SPP contents or configure VCRM to automa

Pagina 108

Component identification 9 Item Description 11 Systems Insight Display 12 USB connector Front panel LEDs and buttons • 8 SFF or 4 LFF Item De

Pagina 109

Troubleshooting 90 Troubleshooting Troubleshooting resources The HP ProLiant Gen8 Troubleshooting Guide, Volume I: Troubleshooting provides procedur

Pagina 110

System battery 91 System battery If the server no longer automatically displays the correct date and time, you may need to replace the battery that

Pagina 111 - Acronyms and abbreviations

System battery 92 To replace the component, reverse the removal procedure. For more information about battery replacement or proper disposal, contac

Pagina 112

Regulatory information 93 Regulatory information Safety and regulatory compliance For safety, environmental, and regulatory information, see Safety

Pagina 113

Regulatory information 94 Valid date formats include the following: • YWW, where Y indicates the year counting from within each new decade, with 20

Pagina 114 - Documentation feedback

Electrostatic discharge 95 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Pagina 115 - Index 115

Specifications 96 Specifications Environmental specifications Specification Value Temperature range* — Operating 10°C to 35°C (50°F to 95°F) Non

Pagina 116 - Index 116

Specifications 97 • HP 750W Common Slot Gold Hot Plug Power Supply (92% efficiency) (on page 99) • HP 750W Common Slot Platinum Plus Hot Plug Powe

Pagina 117 - Index 117

Specifications 98 Rated steady-state power 460 W at 100V to 120V AC input 460 W at 200V to 240V AC input Maximum peak power 460 W at 100V to 120V AC

Pagina 118 - Index 118

Specifications 99 HP 750W Common Slot 277VAC Hot Plug Power Supply (94% efficiency) Specification Value Input requirements Rated input voltage 20

Comentarios a estos manuales

Sin comentarios