D Specications
Chassis (in the desktop position)
Height
Width
Depth
3.74 in
10.63 in
11.65 in
95 mm
270 mm
296 mm
Approximate Weight 9.92 lb 4.5 kg
Weight Supported (maximum distributed load in desktop position) 77 lb 35 kg
Temperature Range
Operating
Nonoperating
50° to 95°F
-22° to 140°F
10° to 35°C
-30° to 60°C
NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained
sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
16,404 ft
50,000 ft
5000 m
15,240 m
Power Supply
Operating Voltage Range
Rated Voltage Range
1
Rated Line Frequency
Operating Line Frequency
90-264 VAC
100-240 VAC
50-60 Hz
47-63 Hz
80 PLUS Bronze 180W active PFC; 82/85/82% ecient at 20/50/100%
load (115V)
80 PLUS Platinum 180W active PFC; 90/92/89% ecient at 20/50/100%
load (115V)
180W active PFC; 91/93/90% ecient at 20/50/100%
load (230V)
Rated Input Current 3.5A
1
This system utilizes an active power factor corrected power supply. This allows the system to pass the CE mark requirements for use
in the countries of the European Union. The active power factor corrected power supply also has the added benet of not requiring an