Maintain the All-in-One
37
Clean the wrist case and hand mount
Use a baby wipe or a cotton cloth dampened with deionized water to scrub all areas of the
hand mount, straps, and wrist case that have come into direct contact with the skin.
Clean the door
To clean the opening in the door, do the following:
IMPORTANT: Do not touch the metal contacts or the ink nozzles.
1. Remove the print cartridge from the door.
2. Use a dry cotton cloth to remove the ink-soaked fibers from the opening in the door.
3. If the ink is too dry to easily remove the fibers, use a cotton swab dampened with deionized
water to break down the ink buildup.
Charge the battery
To charge batteries, follow the instructions that came with your battery charger.
Remove the All-in-One from hand mount
accessory
1. Squeeze both of the release buttons on the back of the hand mount.
2. Slide the hand mount backward, off of the All-in-One.
1
Release button
(one on each side)