Temperature Exceeded
Shows whether the system forces a controller shutdown if a temperature is detected that exceeds
system threshold limits.
Partner Notify
Shows whether the partner controller is notified if a trigger condition occurs.
Auto Write Back
Shows whether the cache mode automatically changes to write-back after the trigger condition is
cleared.
Example Show advanced system-configuration settings:
# show advanced-settings
Background Scrub: enabled
Partner Firmware Upgrade: disabled
Utility Priority: High
SMART: Enabled
Dynamic Spare Configuration: Disabled
Enclosure Polling Rate: 5
Host Control of Caching: enabled
Sync Cache Mode: Immediate
Missing LUN Response: Not Ready
Controller Failure: Disabled
SuperCap Failure: Enabled
CompactFlash Failure: Enabled
Power Supply Failure: Disabled
Fan Failure: Disabled
Temperature Exceeded: Disabled
Partner Notify: Disabled
Auto Write Back: Enabled
See also set advanced-settings