set controller-date
Description Sets the date and time for each Management Controller and then updates the date and time for
each Storage Controller.
Syntax
set controller-date jan|feb|mar|apr|may|jun|jul|aug|sep|oct|nov|dec day
hh:mm:ss year time-zone [ntp enabled|disabled] [ntpaddress IP-address]
Parameters jan|feb|mar|apr|may|jun|jul|aug|sep|oct|nov|dec
The month.
day
The day number (1–31).
hh:mm:ss
The hour on a 24-hour clock (0–23), the minutes (0–59), and the seconds (0–59).
year
The year as a four-digit number.
time-zone
The system's time zone based on an offset from Universal Time (UT) in hours.
ntp enabled|disabled
Optional. Enables use of Network Time Protocol (NTP). If an NTP server is available, the controller's
time is synchronized with the server. When enabling NTP you must specify all the parameters but
only the ntpaddress and time-zone parameters must be set accurately; the other parameters
are ignored. When NTP is enabled, a client task becomes active.
Example Set the controller date to 1:45 PM on September 22, 2006 in the U.S. Mountain time zone (GMT
-07:00):
# set controller-date sep 22 13:45:0 2007 -7
Success: Command completed successfully
Enable NTP using a specified time-zone offset and NTP server address:
# set controller-date sep 22 13:45:0 2007 -7 ntp enabled ntpaddress 69.10.36.3
Success: Command completed successfully
See also show controller-date