set advanced-settings
Description For API use, sets advanced system configuration options.
Syntax
set advanced-settings [auto-write-back enabled|disabled|on|off]
[background-scrub enabled|disabled|on|off]
[compact-flash-failure enabled|disabled|on|off]
[controller-failure enabled|disabled|on|off]
[dynamic-spares enabled|disabled|on|off] [emp-poll-rate rate]
[fan-failure enabled|disabled|on|off]
[host-cache-control enabled|disabled|on|off]
[missing-lun-response notready|illegal]
[partner-firmware-upgrade enabled|disabled|on|off]
[partner-notify enabled|disabled|on|off]
[power-supply-failure enabled|disabled|on|off] [smart enabled|disabled|on|off]
[super-cap-failure enabled|disabled|on|off] [sync-cache-mode immediate|flush]
[temperature-exceeded enabled|disabled|on|off]
[utility-priority low|medium|high]
Parameters auto-write-back enabled|disabled|on|off
Optional. Sets whether the cache mode automatically changes to write-back after the trigger
condition is cleared.
background-scrub enabled|disabled|on|off
Optional. Sets whether disks are automatically checked for disk defects to ensure system health.
compact-flash-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when CompactFlash
memory fails.
controller-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when a controller
fails. The default is disabled.
dynamic-spares enabled|disabled|on|off
Optional. Sets whether the storage system will automatically designate a properly sized disk as a
spare.
emp-poll-rate rate
Optional. Sets the interval at which the storage system polls the EC (EMP) for status changes. The
default is 5 seconds.
fan-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when a fan fails.
host-cache-control enabled|disabled|on|off
Optional. Sets whether the host can modify the cache setting. The default is disabled.
missing-lun-response notready|illegal
Optional. Sets the missing-LUN response which enables the host drivers to continue probing for LUNs
until they reach the LUN to which they have access.
notready: Sends a reply that there is a LUN where a gap has been created but that it's not
ready. Sense data returned is sensekey = 2, code = 4, qualifier = 3. This option is the default.
illegal: Sends a reply that there is a LUN but that the request is illegal. Sense data returned is
sensekey = 5, code = 25h, qualifier = 0.
partner-firmware-upgrade enabled|disabled|on|off
Optional. Sets whether component firmware versions are monitored and will be automatically
upgraded on the partner controller.
partner-notify enabled|disabled|on|off
Optional. Sets whether to notify the partner controller that a trigger condition occurred. Enable this
option to have the partner also change to write-through mode for better data protection. Disable this
option to allow the partner continue using its current caching mode for better performance. The
default is disabled.