• If you use the Create button on an empty slot, the backup application needs to inventory it (add it
to its database or catalog) before it can access it.
• If you use t
he Create button on an empty mail slot, you can use the backup application to move
theblank,newcartridgetoanemptycartridgeslot,withouthavingtorunaninventory. This
saves some processing time.
NOTE:
When you i
mport a c artridge, you need an empty mail slot and an empty cartridge to which the backup
applicat
ion can move the imported data. Therefore, you may wish to leave a slot whose cartridge has
been exp
orted empty, rather than creating a new cartridge. Or to create a slot, edit the Total No Of
Cartridge Slots on the Devices page, see “To edit device details”onpage66.
Network ( Configuration)
This page is used to view and edit network settings. It is also used to turn Beacon Mode on and off.