7. Utility Reference
309
trace_file_number Specify the maximum number of trace files
(
hdlmtr[1-64].log).
You can specify a value from
2 to 64. The
default is
4.
Optional Optional 2
path_health_check Specify whether to enable path health
checking by specifying either of the
following values:
on: Enable path health checking (default).
off: Disable path health checking.
Optional Optional 3
path_health_check_
interval
Specify, in minutes, the interval at which the
path health check will be performed.
You can specify a value from
1 to 1440. The
default is
30.
Optional Optional 4
auto_failback Specify whether to enable automatic
failbacks for failed paths by specifying
either of the following values:
on: Enable automatic failback (default).
off: Disable automatic failback.
Optional Optional 3
auto_failback_inte
rval
Specify, in minutes, the path status check
interval, which is the interval between the
end of the previous check and the start of the
next check.
You can specify a value from
1 to 1440. The
default is 1.
Optional Optional 4
intermittent_error
_monitor
#4 #5
Specify whether to enable intermittent error
monitoring by specifying either of the
following values:
on: Enable intermittent error monitoring.
off: Disable intermittent error monitoring
(default).
Optional Optional 3
intermittent_error
_monitor_interval
#5
Specify, in minutes, the intermittent error
monitoring interval.
You can specify a value from
1 to 1440. The
default is
30.
Optional Optional 4
Key name
#1
Description
#2
Necessity of
definition
Maximu
m
charact
er
length
#3
New
installati
on
Upgrad
e
installati
on or
Re-insta
llation