Hp StorageWorks XP10000 Disk Array Manual de usuario Pagina 152

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 178
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 151
Table 19 LUN Manager Spreadsheet Format
Column
Function Tag
[CHA]
[Port] [Host-
Group]
[WWN] [LUN] [LDEV]
1st
CHA
Port Port Port Port
CU
2nd PCB Mode
Security
Switch
Group ID Group ID Group ID
LDEV
3rd Blank
AL-PA Name WWN LUN
Command
Device
4th Blank Fabric Host mode
Name
CU
Command
Device
Security
5th Blank
Connection
Host mode
option
Blank
LDEV
Blank
6th Blank Channel
speed
Blank Blank Blank
7th Blank
8th Blank
9th Blank
10th Blank
11 t h
CHA
Port Port Port Port
CU
12 t h PC B M o d e
Security
Switch
Group ID Group ID Group ID
LDEV
13th Blank
AL-PA Name WWN LUN
Command
Device
14th Blank Fabric Host mode
Name
CU
Command
Device
Security
15th Blank
Connection
Host mode
option
Blank
LDEV
Blank
16th Blank Channel
speed
Blank Blank
NOTE:
When the LUN Manager spreadsheet is exported, the settings are written up to the 10th column
(blank column).
For detailed information on LUN Manager, including the available values and the relationships between
each function, see the HP StorageWorks XP LUN Conguration and Security Manager user guide. LUN
Manager spreadsheets must conform to those parameters.
Setting the C
HA Mode
The [CHA] tag
allows you to set the channel adapter mode. The [CHA] tag is available only for changing
settings. Y
ou cannot add or delete the settings with the [CHA] tag denitions. Mainframe settings are not
written on the exported spreadsheet.
You cannot change the NAS settings using the spreadsheet. However, the current NAS settings are
commented o
n the exported spreadsheet (the rows start with “#$”).
152
Conguration File Loader
Vista de pagina 151
1 2 ... 147 148 149 150 151 152 153 154 155 156 157 ... 177 178

Comentarios a estos manuales

Sin comentarios