Second Error Check
In the second che
ck, the spreadsheet settings are verified. Any errors found are displayed on the Error
Information li
st. This second check is performed before the Apply button becomes available. Figure 119
shows the flow of
the second check.
The second error check consists of two different types of the checks. These checks are shown in Figure 119
as the Level 1 and Level 2. The Level 2 check is performed only when no error is found by the Level 1
check. Each level of the check of the second error check detects the following errors:
• Level 1 check (
the format and parameters are checked):
• A function tag is not supported.
• A setting value is incorrect or omitted.
•The setting r
ange is incorrect. The correct ranges are as follows:
CU: 00 - 3F
LDEV: 00 - FF
LUN: 0000 - 03
FF
Group ID: 00 - FE
Host Mode: 00 - 2F
• Level 2 check
:
The current settings are compared to the imported settings and checked for logical consistency. Note
that certain errors can only be detected by the third check.
When you impo
rt a spreadsheet with no errors detected, the pane displays Ready above the error
information list, and the Apply button becomes available.
HP StorageWorks