Specifications 89
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
10°C to 35°C (50°F to 95°F)
Non-operating
-30°C to 60°C (-22°F to 140°F)
Relative humidity
(non-condensing)
Operating, maximum wet bulb
temperature of 28°C (82.4°F)
10% to 90%
Non-operating, maximum wet
bulb temperature of 38.7°C
(101.7°F)
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
Mechanical specifications
Specification Value
Dimensions
Height
4.44 cm (1.75 in)
Depth
70 cm (27.56 in)
Width
44.8 cm (17.64 in)
Weight (maximum)
14.26 kg (31.4 lb)
Weight (one hard drive
installed))
10.37 kg (22.84 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
HP ProLiant ATX 400 W power supply
Specification Value
Input requirements
Rated input voltage
100 to 240 VAC
Rated input frequency
47 Hz to 63 Hz
Rated input current
Limit at 6 A
Rated input power
570 W at 115 VAC
Power supply output