
Operations 29
CAUTION: For proper cooling do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components,
minimize the amount of time the access panel is open.
1. Power down the server (on page 22).
2. Extend or remove the server from the rack ("Extend the server from the rack" on page 22).
3. Remove the access panel (on page 23).
CAUTION: Do not detach the cable that connects the battery pack to the cache module.
Detaching the cable causes any unsaved data in the cache module to be lost.
4. Remove the battery pack from the air baffle.
5. Remove the air baffle.
Hot-plug fan operation
CAUTION: To avoid damage to server components, fan blanks must be installed in fan bays
5 and 6 in a single-processor configuration.
The only two valid fan configurations are listed in the following table.
Configuration
Fan bay
1
Fan bay
2
Fan bay 3
Fan bay
4
Fan bay
5
Fan bay 6
1 processor Fan Fan Fan Fan Fan blank Fan blank
2 processors Fan Fan Fan Fan Fan Fan
Comentarios a estos manuales