Component identification 9
Systems Insight Display LEDs and health LED
combinations
When the health LED on the front panel illuminates either amber or red, the server is experiencing a
health event. Combinations of illuminated system LEDs and the health LED indicate system status.
Systems Insight Display
LED and color
Health LED
color
Status
Processor (amber) Red One or more of the following conditions may exist:
Processor in socket X has failed.
Processor X is not installed in the socket.
Processor X is unsupported.
ROM detects a failed processor during POST.
Amber Processor in socket X is in a pre-failure condition.
DIMM (amber) Red DIMM in slot X has failed.
Amber DIMM in slot X is in a pre-failure condition.
DIMM (amber) Red
One or more DIMMs have failed. Test each bank of
DIMMs by removing all other DIMMs. Isolate the failed
DIMM by replacing each DIMM in a bank with a known
working DIMM.
Overtemperature (amber) Amber
The Health Driver has detected a cautionary temperature
level.
Red
The server has detected a hardware critical temperature
level.
Fan (amber) Amber One fan is failed or removed.
Red Two or more fans have failed or are missing.
Power supply (amber) Red Only one power supply is installed and is in standby.
Power supply fault
System board fault
Power supply (amber) Amber
Redundant power supply is installed and only one power
supply is functional.
AC power cord not plugged into redundant power
supply
Redundant power supply fault
Power supply (amber) Amber
Power supply mismatch at POST or power supply
mismatch through hot add
Comentarios a estos manuales