Component identification 15
administrators is to restart the system. Resetting the system erases any information which could support
problem analysis, but the NMI feature preserves that information by performing a memory dump before a
system reset.
To force the system to invoke the NMI handler and generate a crash dump log, do one of the following:
Use the iLO Virtual NMI feature.
Short the NMI header ("System board components" on page 12).
For more information, see the HP website (http://www.hp.com/support/NMI).
Drive numbering
In an 8-bay drive cage, when only one SATA cable is connected, the server can only support a 4-drive
configuration. In this configuration, drive bays 1 through 4 are populated, while drive bays 5 through 8 have
drive blanks.
When the two-port SATA cable option ("Two-port SATA cable option" on page 44) is connected, the server
supports a 6-drive configuration. In this configuration, drive bays 1 through 6 are populated, while drive
bays 7 and 8 have drive blanks.
8-bay SFF drive model
8-bay LFF drive model
8+8-bay SFF drive model