Hardware options installation 46
8.
Connect the common end of the Mini-SAS Y-cable to the controller option.
9. Install the PCI riser cage ("Install the PCI riser cages" on page 25).
10. Route the split ends of the Mini-SAS Y-cable along the side of the system board towards the front chassis,
and then connect the cable to the drive backplane.
The Mini-SAS cable routing from the secondary PCI riser cage is only supported in the 8+8 SFF drive
configuration.
11. Connect the rest of the drive cables required in this drive configuration. For more information, see
"Storage cabling (on page 81)."
12. Install the PCI riser cage ("Install the PCI riser cages" on page 25).
13. If you intend to use an FBWC module and capacitor pack, install these options now ("Installing the
FBWC module and capacitor pack" on page 49).
14. Install the air baffle (on page 23).
15. Install the access panel (on page 23).
16. Install the server into the rack ("Installing the server into the rack" on page 32).
17. Power up the server (on page 19).
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
18. Install the drives ("Installing a hot-plug drive" on page 36).
Mini-SAS Y-cable options
The Mini-SAS Y-cables in these option kits support the following drive configurations.
Drive configuration Mini-SAS Y-cable required
8 LFF
690 mm
8 SFF
540 mm
8+8 SFF*
*
This drive configuration requires the installation of two HP Smart Array P430 controller boards in the full-height side of
the primary PCI riser cage.
To connect the cable option:
1. Power down the server (on page 19).
2. Remove all power:
a. Disconnect each power cord from the power source.