Operations 32
4.
Do one of the following:
o For tower models, place the server on a flat, level surface with the access panel facing up.
o For rack models, extend the server from the rack (on page 27).
5. Remove the access panel (on page 25).
6. If installed, remove the PCI air baffle (on page 28).
7. Remove any installed full-length PCI expansion cards ("Remove a full-length expansion board" on page
37).
8. Remove the system air baffle (on page 30).
9. Remove the fan cage:
a. Disconnect all fan connectors from the system board.
b. Loosen the thumbscrews on either side of the fan cage.
c. Remove the fan cage from the server.