Hp ProLiant ML370 G5 Server Manual de usuario Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 135
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
Component identification 15
NOTE: The system management driver must be installed for the internal system health LED to
provide pre-failure and warranty conditions.
The front panel health LEDs indicate only the current hardware status. In some situations, HP SIM may
report server status differently than the health LEDs because the software tracks more system attributes.
HP Systems Insight
Display LED color
Internal system
health LED color
Status
Processor failure,
socket X (amber)
Red One or more of the following conditions may exist:
Processor in socket X has failed.
Processor X is not installed in the socket.
ROM detected a failed processor during POST.
Amber Processor in socket X is in a pre-failure condition.
PPM failure, slot X
(amber)
Red One or more of the following conditions may exist:
PPM in slot X has failed.
PPM is not installed in slot X, but the corresponding
processor is installed.
DIMM failure, slot X
(amber)
Red One or more of the following conditions may exist:
DIMM in slot X has failed.
DIMM has experienced a multi-bit error.
Amber One or more of the following conditions may exist:
DIMM in slot X has reached single-bit correctable error
threshold.
DIMM in slot X is in a pre-failure condition.
DIMM bank error (all
slots in one bank,
amber)
Red One or more of the following conditions may exist:
The bank is not populated entirely.
All DIMMs in the bank do not match.
Memory riser board is missing or not fully seated.
DIMM failure (all
slots, amber)
Red One or more of the following conditions may exist:
No valid or usable memory is installed in the system.
The banks are not populated in the correct order.
Overtemperature alert
(amber)
Red System temperature has exceeded OS cautionary level or
critical hardware level.
Fan (amber) Red A required fan has failed.
Amber A redundant fan has failed.
SAS and SATA device numbers
The server supports a combination of up to 16 SAS and SATA hard drives in two hard drive cages.
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 134 135

Comentarios a estos manuales