Hardware options installation 66
Array controllers and Battery-Backed Write Cache
options
For a list of supported options, refer to the Documentation CD or the QuickSpecs on the HP website
(http://www.hp.com/servers/proliantml370
).
Parallel and second serial connector option
To install the component:
1. Power down the server (on page 20).
2. Do one of the following:
o Open or remove the tower bezel, as needed ("Open or remove the tower bezel" on page 21).
o Extend the server from the rack (on page 22).
3. Remove the access panel (on page 25).
4. Remove an expansion slot cover ("Expansion slot cover" on page 62).
5. Install the parallel and serial connector bracket and close the slot release lever.
6. Connect the parallel and serial cables to the parallel and serial connectors on the system board.
7. Install the access panel (on page 26).
8. Do one of the following:
o Close or install the tower bezel, as needed.
o Slide the server back into the rack.
9. Power up the server (on page 20).
10. Enable the feature under the System Options menu in RBSU. For more information on RBSU, refer to
the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website
(http://www.hp.com/servers/smartstart
).