Diagnostics and Status
166 Fabric OS Procedures Version 3.1.x/4.1.x User Guide
Options are provided to the errdump command to display three options: all
the errors (previous persistent log and the current run-time log), only errors
from the current run-time cycle, or the errors from the persistent error log.
Options are provided to clear the persistent error log. (errclear –p).
Note: Only the persistent log can be resized. The run-time error log cannot be resized.
Displaying the Error Log Without Page Breaks
To display the switch error log all at once:
1. Log into the switch as the admin user.
2. Enter the errdump command at the command line.
Example:
switch:admin> errdump
Error 04
--------
0x576 (fabos): Nov 25 08:26:44 (1)
Switch: 1, Info TRACK-LOGIN, 4, Successful login
Error 03
--------
0x576 (fabos): Nov 24 16:01:44 (12)
Switch: 1, Info TRACK-CONFIG_CHANGE, 4, Config file change from task:ZNIPC
Error 02
--------
0x2f0 (fabos): Nov 24 15:07:01
Switch: 1, Warning FW-STATUS_SWITCH, 3, Switch status changed from
HEALTHY/OK to
Marginal/Warning