Troubleshooting
214 Fabric OS Procedures Version 3.1.x/4.1.x User Guide
4. Enter the portErrShow command. Check for errors that may cause login
problems.
A high number of errors relative to the frames transmitted and frame
received may indicate a marginal link. See “Marginal Links” on page 234.
A steadily increasing number of errors may indicate a problem. Track
errors by sampling the port errors every five or ten seconds.
Example:
switch:admin> portflagsshow
Port SNMP Physical Flags
-------------------------------
0: Offline No_Module PRESENT U_PORT LED
1: Offline No_Module PRESENT U_PORT LED
2: Offline No_Light PRESENT U_PORT LED
3: Offline No_Light PRESENT U_PORT LED
4: Offline No_Light PRESENT U_PORT LED
5: Offline No_Module PRESENT U_PORT LED
6: Offline No_Module PRESENT U_PORT LED
7: Offline No_Module PRESENT U_PORT LED
8: Offline No_Module PRESENT U_PORT LED
9: Offline No_Module PRESENT U_PORT LED
10: Offline No_Module PRESENT U_PORT LED
11: Offline No_Module PRESENT U_PORT LED
12: Offline No_Module PRESENT U_PORT LED
13: Offline No_Module PRESENT U_PORT LED
14: Offline No_Module PRESENT U_PORT LED
15: Offline No_Module PRESENT U_PORT LED
16: Online UNKNOWN PRESENT ACTIVE G_PORT U_PORT
switch:admin>