Server Error Messages
The following POST error message is new and unique to some HP ProLiant servers:
A processor thermal event occurred prior to this power
up, Processor X
This message indicates that processor X (1 or 2) has reached an excessive
temperature and has stopped operation. Verify the following information:
The processor and heatsink assembly is properly installed. ·
· Ambient temperature is within an acceptable range.
Refer to Appendix F, “Specifications,” for operational temperature
requirements.
For a complete listing of error messages provided for the server, refer to the Servers
Troubleshooting Guide in your user documentation.